Logo PUC-Rio Logo Maxwell
ETDs @PUC-Rio
Estatística
Título: EXPERIMENTAL STUDY OF TORSIONAL STRENGTHENING OF CONCRETE BEAMS WITH CARBON FIBERS COMPOSITES
Autor: TATHIANA CARAM SOUZA DE PAULA FIGUEIREDO
Colaborador(es): MARTA DE SOUZA LIMA VELASCO - Orientador
EMIL DE SOUZA SANCHEZ FILHO - Coorientador
Catalogação: 13/DEZ/2021 Língua(s): PORTUGUESE - BRAZIL
Tipo: TEXT Subtipo: THESIS
Notas: [pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio.
[en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio.
Referência(s): [pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=56532&idi=1
[en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=56532&idi=2
DOI: https://doi.org/10.17771/PUCRio.acad.56532
Resumo:
This research is an experimental study of torsion strengthening of concrete beams with carbon fibers composites. Thirteen concrete beams with 2.0 long and 30 x 60 cm cross section were tested in the Structures and Materials Laboratory of the Civil Engineering Department (LEM/DEC) of Pontifical Catholic University of Rio de Janeiro (PUC-Rio). The beams were divided in four series, the first one was called the reference series and consisted of four beams without external strengthening and each of the other three series was composed of three beams strengthened with increasing rates of external carbon fibers composites stirrups. In oder to allow the study of the central region without the contribution of the steel reinforcement, the internal steel reinforcement was placed only at points of loads application and supports to prevent the local rupture. The tests results showed that the strengthened beams had an increase of the cracking load between 16 per cent and 56 per cent, and an increase of the rupture load between 19 per cent and 47 per cent when compared to the reference beams. The ultimate resistance of the beams increased proportionally to the rate of external carbon fibers composites strengthening, as was observed by other researchers.
Descrição: Arquivo:   
COVER, ACKNOWLEDGEMENTS, RESUMO, ABSTRACT, SUMMARY AND LISTS PDF    
CHAPTER 1 PDF    
CHAPTER 2 PDF    
CHAPTER 3 PDF    
CHAPTER 4 PDF    
CHAPTER 5 PDF    
CHAPTER 6 PDF    
REFERENCES AND ANNEX PDF