[pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio. [en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio. |
|||||||
Referência(s): |
[pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=12414&idi=1 [en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=12414&idi=2 |
|||||||
DOI: | https://doi.org/10.17771/PUCRio.acad.12414 | |||||||
Resumo: | ||||||||
This work shows a study of the weldability of API 5L X-80
steel using the
Tekken Test and the Implant Test. The research analises the
weldability of HSLA
X-80 steel for orbital circunferencial welding with the
Shielded Metal Arc Weld
and the Flux Core Arc Weld processes with regard to
hydrogen induced cracking
formation. The aim is to make feasible different options of
welding process for the
steel at issue. For the Tekken Test two pairs of plates
were welded by SMAW
process using E8010-G consumable and two more pairs by FCAW-
G process
using E101-T1-GM-H8. The Implant Test used three base
plates and ten implants,
being four implants welded by SMAW process and with E8010-G
consumable
and six by FCAW-G process with E101T1-GM-H8 consumable. All
the implants
have 6 mm of diameter. For all tests the preheating
temperature was 100°C. The
diffusible hydrogen content deposited by both consumables
was measured by the
Gas Chromatography Method. After the tests all the samples
were examined
without and with attack by means of optical microscope and
SEM to allow
hydrogen induced cracking in the HAZ and in the weld metal
(for Tekken Test) to
be viewed and measured. By means of this procedure it was
possible to observe
that all samples showed transgranular cracking with length
of 17,68 um, too small
and unlikely to the be bad to the steel. It allows saying
that X-80 steel can be
welded using the consumables tested, without a risk of
damage of the material.
|
||||||||