Maxwell Para Simples Indexação

Título
[en] METHODOLOGY FOR DETERMINING THE POTENTIAL MARKET OF A MICROTURBINE BASED COGENERATION SYSTEM FOR ELECTRIC ENERGY AND HOT WATER PRODUCTION

Título
[pt] METODOLOGIA PARA DETERMINAÇÃO DO MERCADO POTENCIAL DE UM SISTEMA DE COGERAÇÃO COM MICROTURBINA PARA PRODUÇÃO DE ENERGIA ELÉTRICA E ÁGUA QUENTE

Autor
[pt] JOAO VIEIRA DE ARAUJO

Vocabulário
[pt] METROLOGIA

Vocabulário
[pt] DESEMPENHO

Vocabulário
[pt] COGERACAO

Vocabulário
[pt] GERACAO DISTRIBUIDA

Vocabulário
[pt] INCERTEZA

Vocabulário
[en] METROLOGY

Vocabulário
[en] ACHIEVEMENT

Vocabulário
[en] COGENERATION

Vocabulário
[en] DISTRIBUTED GENERATION

Vocabulário
[en] UNCERTAINTY

Resumo
[pt] O uso seqüencial de energia elétrica e energia térmica a partir da energia química do mesmo combustível tem sido estudado para melhorar o custo benefício de uma geração distribuída. O objetivo deste estudo é determinar o mercado potencial desta tecnologia na região de influência da concessionária local de energia elétrica. Para alcançar este objetivo, foi necessário avaliar o desempenho de um sistema de cogeração com uma microturbina fornecendo potência elétrica e energia térmica através dos gases de exaustão que aquecem água para o ginásio esportivo da PUC-Rio. O sistema está configurado por uma microturbina, uma caldeira de recuperação, um reservatório térmico (boiler) e uma caixa para alimentação de água fria. Resultados obtidos de testes de curta duração, através de uma metodologia desenvolvida, para a avaliação do desempenho do sistema de cogeração na produção de energia elétrica e térmica, são apresentados. Os testes foram realizados para potências elétricas de 100, 75, 50 e 25 % da carga máxima da microturbina. Em adição, testes para avaliação do desempenho ao longo do tempo em função das variações da carga e das condições ambientais foram estudados. Além disso, através de uma metodologia desenvolvida, mostram-se os resultados nos cálculos de incerteza dos parâmetros analisados. Dados de consumo de energia elétrica em janeiro de 2003, de cerca de 8000 consumidores na área de concessão da LIGHT SESA, em diferentes classes tarifárias, atualizadas para 2007, foram utilizados com a metodologia desenvolvida para estimar o mercado potencial de energia elétrica na região de influência da concessionária local de energia elétrica em 384,5 MW e 20415 MWh/mês, considerando uma taxa interna de retorno mínimo de 15% a.a. Foi mostrado que o elevado custo da microturbina é uma barreira para sua introdução no mercado. Entretanto, a cogeração pode colaborar substancialmente para melhorar o custo benefício. Estas conclusões foram obtidas a partir do tempo de retorno do investimento no sistema pelos consumidores analisados.

Resumo
[en] The sequential use of electric energy and thermal energy from the chemical energy of the same fuel has been studied to improve the cost benefit of a distributed generation. The objective of this study is to evaluate the potential market of this technology in the region of influence of the local utility of electric energy.utility company (LIGHT). In order to attain this objective, it was necessary to evaluate the performance of a micro turbine based cogeneration system used for supplying electrical and thermal energy to PUC-RIO´S Gymnasium. The system consists of a microturbine, a heat recovery boiler, and a cold water feeding reservoir. The short duration test results are presented for the evaluation of the cogeneration system performance for the production of electric and thermal energy. The tests were carried on for 100, 75, 50 and 25% micro turbine electric energy generation loads. Time performance of the micro turbine was also studied. Moreover, a methodology was shown to calculate the uncertainty of measurements of several performance parameters. The micoturbine marked potential was estimated by analyzing the consumption of about 8000 clients in January 2003, updating the tariffs to 2007, resulting in 384,5 MW and 20415 MWh/month, considering a minimum internal rate of return of investiment of 15% per year, during a 15 year period. It was concluded that the microturbine cost is still a barrier to its market penetration. Cogeneration can be used to improve the cost benefit of the system.

Orientador(es)
ALCIR DE FARO ORLANDO

Banca
JOSE ALBERTO DOS REIS PARISE

Banca
ELOI FERNANDEZ Y FERNANDEZ

Banca
ALCIR DE FARO ORLANDO

Banca
CARLOS EDUARDO REUTHER DE SIQUEIRA

Catalogação
2007-10-11

Apresentação
2007-04-20

Tipo
[pt] TEXTO

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=10708@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=10708@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.10708


Arquivos do conteúdo
CAPA, AGRADECIMENTOS, RESUMO, ABSTRACT, SUMÁRIO E LISTAS PDF
CAPÍTULO 1 PDF
CAPÍTULO 2 PDF
CAPÍTULO 3 PDF
CAPÍTULO 4 PDF
CAPÍTULO 5 PDF
CAPÍTULO 6 PDF
CAPÍTULO 7 PDF
REFERÊNCIAS BIBLIOGRÁFICAS E APÊNDICES PDF