Logo PUC-Rio Logo Maxwell
ETDs @PUC-Rio
Estatística
Título: THEORETICAL AND EXPERIMENTAL ANALYSIS OF A COMPOSITE SEMI-RIGID BEAM-TO-COLUMN JOINT USING PERFOBOND SHEAR CONNECTORS
Autor: RAQUEL ALVES CABRAL SILVA
Colaborador(es): SEBASTIAO ARTHUR LOPES DE ANDRADE - Orientador
Catalogação: 03/OUT/2016 Língua(s): PORTUGUESE - BRAZIL
Tipo: TEXT Subtipo: THESIS
Notas: [pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio.
[en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio.
Referência(s): [pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=27553&idi=1
[en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=27553&idi=2
DOI: https://doi.org/10.17771/PUCRio.acad.27553
Resumo:
In engineering design it is common to disregard the semi-rigid behavior of connections, i.e., connections are assumed to have the ideal conditions of rigidity. The first ideal condition is the one in which there is full transfer of bending moment, assuming that there is no relative rotation between the connected elements, this connection is defined rigid. In the second option, the transfer of bending moment is disregarded and the connection is defined simple. However, it is known that most connections have a semi-rigid behavior and the problem is that when making these simplifications in design, two aspects can be compromised: structural safety and project cost. In this work, a composite semi-rigid connection is studied in order to obtain its main and necessary features to use it in design: moment-rotation curve, service rigidity and bending moment capacity. With the proposed composite connection, a new way to transfer forces in the negative moment region on a semicontinous beam. Shear connectors like the Perfobond Rib were adopted for the transfer of efforts between the concrete slab and the steel beam. This connector was first used on bridges and since then some studies have made possible its use in buildings, showing its advantages over the more usual connectors. To achieve this work s objectives, two real scale tests of the proposed connections were conducted. Experimental tests were done in inverted cruciform models and carried out in the laboratory of structures and materials at PUC-Rio. Information on these tests was obtained, such as displacements, strains, and cracking of the slab. The experimental results were compared to two analytical models: the method proposed by Leon et al. in 1996 and the present method in Annex R of NBR 8800: 2008.
Descrição: Arquivo:   
COVER, ACKNOWLEDGEMENTS, RESUMO, ABSTRACT, SUMMARY AND LISTS PDF    
CHAPTER 1 PDF    
CHAPTER 2 PDF    
CHAPTER 3 PDF    
CHAPTER 4 PDF    
CHAPTER 5 PDF    
CHAPTER 6 PDF    
CHAPTER 7 PDF    
CHAPTER 8 PDF    
REFERENCES PDF