Título: | STUDY OF THE MEASURING METHOD OF THERMAL CONDUCTIVITY AND WATER CONTENT BY MEANS OF SPHERICAL GEOMETRY: APPLICATIONS ON AQUEOUS SOLUTIONS OF ETHANOL | ||||||||||||||||||||||||||||||||||||||||
Autor: |
JULIO DUTRA BRIONIZIO |
||||||||||||||||||||||||||||||||||||||||
Colaborador(es): |
ALCIR DE FARO ORLANDO - Orientador GEORGES HENRI BONNIER - Coorientador |
||||||||||||||||||||||||||||||||||||||||
Catalogação: | 16/SET/2013 | Língua(s): | PORTUGUESE - BRAZIL |
||||||||||||||||||||||||||||||||||||||
Tipo: | TEXT | Subtipo: | THESIS | ||||||||||||||||||||||||||||||||||||||
Notas: |
[pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio. [en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio. |
||||||||||||||||||||||||||||||||||||||||
Referência(s): |
[pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=22034&idi=1 [en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=22034&idi=2 |
||||||||||||||||||||||||||||||||||||||||
DOI: | https://doi.org/10.17771/PUCRio.acad.22034 | ||||||||||||||||||||||||||||||||||||||||
Resumo: | |||||||||||||||||||||||||||||||||||||||||
The aim of this thesis is the experimental and theoretical study, following
the good metrological practices, of a method based on a spherical heat source in
order to measure thermal conductivity of liquids, focusing on aqueous solutions of
ethanol, with later determination of the water content of the substance. The study
and the development of measuring methods of thermal conductivity are essentials
in several engineering applications, since as a consequence of the current justified
demands on saving and rational use of thermal energy, the heat transfer with the
maximum efficient as possible is of great relevance. The measurement of the
water content is also a relevant parameter in several research areas and industrial
sectors, since the quantity of water in the substances influences several biological,
chemical and physical processes. However, the amount of equipment available on
the market for the measurement of both quantities is not vast. The heated sphere
method, in principle, is an absolute one for the measurement of the thermal
conductivity, which means that the sensor may furnish a result without a
calibration. Nevertheless, some parameters of the model need to be analyzed
separately or obtained by means of calibration. Although there are some studies
on this method, few of them have liquids as the main focus. Moreover, these
studies do not correlate the thermal conductivity of the material with its water
content, and they do not perform a more careful metrological analysis in order to
determine the measurement uncertainties. The applicability of the method to
measure the thermal conductivity and the water content of the analyzed substances
proved to be satisfactory, because the obtained results of this study presented a
very good agreement with the values proposed by several researches and with the
measurements performed at Inmetro by other methods.
|
|||||||||||||||||||||||||||||||||||||||||
|