[pt] CONFIABILIDADE METROLÓGICA DE VENTILADORES PULMONARES

Título
[en] METROLOGICAL RELIABILITY OF LUNG VENTILATORS

Autor
[pt] JORGE CALDERON ROMERO

Vocabulário
[pt] METROLOGIA

Vocabulário
[pt] EQUIPAMENTO ELETROMEDICO

Vocabulário
[pt] VENTILADOR PULMONAR

Vocabulário
[pt] MEDICAO

Vocabulário
[pt] CONFIABILIDADE METROLOGICA

Vocabulário
[en] METROLOGY

Vocabulário
[en] ELECTROMEDICAL EQUIPMENT

Vocabulário
[en] PULMONARY VENTILATOR

Vocabulário
[en] MEASUREMENT

Vocabulário
[en] RELIABLE MEASUREMENT PRACTICES

Resumo
[pt] O presente trabalho apresenta a avaliação da garantia da confiabilidade metrológica de um equipamento eletromédico (EEM), o ventilador pulmonar, também conhecido como ventilador mecânico. A falta de confiabilidade metrológica nesses equipamentos pode resultar na ocorrência de efeitos danosos, conforme a sua qualificação quanto ao potencial de risco à saúde dos usuários (operadores e pacientes). Apesar de ser fundamental para garantir o efeito desejado, a avaliação da confiabilidade geralmente não é realizada durante o período de uso (póscomercialização). Considerando a falta de informação em metrologia no ambiente da saúde e os poucos estudos de metrologia aplicados a esta área indicando os riscos da falta de avaliação metrológica, é de especial relevância a realização de investigações neste campo de pesquisa. Na presente dissertação foram realizadas medições para avaliação da confiabilidade metrológica de ventiladores pulmonares utilizando informações técnicas e normativas. Realizou-se um estudo bibliográfico minucioso dos princípios básicos de funcionamento dos ventiladores pulmonares e suas especificações técnicas. Para a realização das medições foram estudadas referências tais como normas nacionais e internacionais, manuais dos fabricantes do equipamento e publicações sobre manutenção de EEM. Medições para a avaliação metrológica de dez (10) ventiladores pulmonares, 6 da marca I modelo I.1 e 4 da marca II modelo II.2, foram realizadas em um hospital público. A exceção de um ventilador novo, todos os ventiladores pulmonares avaliados apresentaram não conformidades. Os resultados obtidos na avaliação da confiabilidade metrológica dos ventiladores pulmonares assinalam a urgente necessidade de avaliação metrológica periódica destes EEM. Verificou-se também a necessidade de avaliação de parâmetros cuja obrigatoriedade de medição não consta na norma aplicável. De uma forma ampla, o presente trabalho contribui para a conscientização de profissionais da saúde e da área de metrologia quanto à importância da avaliação da confiabilidade metrológica periódica de ventiladores pulmonares.

Resumo
[en] The present Masters dissertation evaluates the metrological reliability of pulmonary ventilators, also known as mechanical ventilators. Pulmonary ventilators are electromedical equipment (EEM). The absence of metrological reliability of a pulmonary ventilator may result in dangerous consequences, according to its classification by the potential risk to the health of users (operators and patients). Even though it is of fundamental importance to guarantee the desired effect, the evaluation of reliability, in general, is not performed during the post-sale period. Considering the lack of information in metrology in the field of health, and that there are few studies indicating the risks of the absence of metrological evaluations, research in this field are especially relevant. In the present dissertation, measurements based on technical and regulatory information were performed in order to evaluate the metrological reliability of pulmonary ventilators. A meticulous bibliographical study of the basic principles and technical specifications of pulmonary ventilators was performed. The measurements were based on national and international standards, manufacturer manuals, and EEM maintenance publications. Measurements for the metrological evaluation of ten (10) pulmonary ventilators, 6 of brand I model I.1 and 4 of brand II model II.2, were performed in a public hospital. Except for a new unit, all evaluated pulmonary ventilators presented non- conformities. These results indicate an urgent need for periodic metrological evaluations of these EEMs. In addition, the need for evaluations of parameters not included in the current standards was verified. The present work contributes for increasing the awareness of health and metrology professionals regarding the importance of periodical evaluations of the metrological reliability of pulmonary ventilators.

Orientador(es)
ELISABETH COSTA MONTEIRO

Coorientador(es)
PAULA MEDEIROS PROENCA DE GOUVEA

Banca
MAURO SPERANZA NETO

Banca
CARLOS ROBERTO HALL BARBOSA

Banca
ELISABETH COSTA MONTEIRO

Banca
PAULA MEDEIROS PROENCA DE GOUVEA

Banca
MARCELO LUIZ CARVALHO GONCALVES

Catalogação
2006-11-01

Apresentação
2006-04-12

Tipo
[pt] TEXTO

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=9233@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=9233@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.9233


Arquivos do conteúdo
CAPA, AGRADECIMENTOS, RESUMO, ABSTRACT, SUMÁRIO E LISTAS PDF
CAPÍTULO 1 PDF
CAPÍTULO 2 PDF
CAPÍTULO 3 PDF
CAPÍTULO 4 PDF
CAPÍTULO 5 PDF
CAPÍTULO 6 PDF
CAPÍTULO 7 PDF
REFERÊNCIAS BIBLIOGRÁFICAS PDF