Título
[pt] CARACTERIZAÇÃO DE UMA BOMBA PIEZOELÉTRICA PULSÁTIL DE BAIXA FREQUÊNCIA
Título
[en] CHARACTERIZATION OF A LOW-FREQUENCY PULSATILE PIEZOELECTRIC PUMP
Autor
[pt] ALAN DE OLIVEIRA PINTO NEVES
Vocabulário
[pt] BOMBA PIEZOELETRICA
Vocabulário
[pt] BOCAL DIFUSOR
Vocabulário
[pt] VALVULA TESLA
Vocabulário
[en] PIEZOELECTRIC PUMP
Vocabulário
[en] NOZZLE DIFFUSER
Vocabulário
[en] TESLA VALVE
Resumo
[pt] Este trabalho buscou caracterizar experimentalmente uma micro bomba
piezoelétrica com válvulas sem partes móveis. Essas bombas são tipicamente
compactas, de baixa vazão (ml/min), de baixo consumo e tem aplicações em
diversas áreas dentre as quais destaca-se a área biomédica para administração
controlada de fármacos. O objetivo neste trabalho foi caracterizar o escoamento
no interior do dispositivo e para isso foram selecionadas três configurações:
uma com válvulas do tipo Tesla de dois canais, outra com válvulas do
tipo Tesla de quatro canais e uma com válvula do tipo cônica. Cada uma
das configurações foi avaliada sob condições de fluxo pulsátil e contínuo. A
caracterização do escoamento no interior de bombas e das válvulas, através
de medições dos campos de velocidade ainda não é reportada na literatura.
Portanto, o presente trabalho buscou contribuir neste tópico. Os resultados
obtidos com os dispositivos testados indicaram que existe uma frequência
ótima de operação da bomba e que confere a maior vazão. Nos dispositivos
avaliados essa frequência foi de 10Hz. A maior diferença entre o fluxo direto
e reverso para o modo contínuo foi encontrado na configuração bocal/difusor.
Por fim, os campos de velocidade internos das válvulas foram analisados por
meio da técnica de Velocimetria por Imagem de Partículas (PIV). Espera-se
que a caracterização detalhada dessas bombas, aliada às medições de PIV,
contribua para o desenvolvimento das bombas piezoelétricas.
Resumo
[en] This study aimed to experimentally characterize a piezoelectric microp
ump with valves that have no moving parts. These pumps are typically com
pact, have low flow rates (ml/min), low power consumption, and are used in
various fields, particularly in the biomedical area for controlled drug deliv
ery. The objective of this work was to characterize the flow inside the device,
and for this purpose, three configurations were selected: one with two-channel
Tesla-type valves, another with four-channel Tesla-type valves, and one with
conical-type valves. Each configuration was evaluated under pulsatile and con
tinuous flow conditions. The characterization of the flow within pumps and
valves through velocity field measurements has not yet been reported in the
literature. Therefore, this work aimed to contribute to this topic.The results ob
tained from the tested devices indicated the existence of an optimal operating
frequency for the pump, which yields the highest flow rate. For the evaluated
devices, this frequency was 10 Hz. The greatest difference between forward
and reverse flow in continuous mode was found in the nozzle/diffuser config
uration. Finally, the internal velocity fields of the valves were analyzed using
Particle Image Velocimetry (PIV). It is expected that the detailed character
ization of these pumps, together with the PIV measurements, will contribute
to the development of such devices.
Orientador(es)
IGOR BRAGA DE PAULA
Banca
MARIA HELENA FARIAS
Banca
IGOR BRAGA DE PAULA
Banca
RAFAEL MENEZES DE OLIVEIRA
Catalogação
2025-08-21
Apresentação
2025-05-21
Tipo
[pt] TEXTO
Formato
application/pdf
Idioma(s)
PORTUGUÊS
Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=72588@1
Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=72588@2
Referência DOI
https://doi.org/10.17771/PUCRio.acad.72588
Arquivos do conteúdo
NA ÍNTEGRA PDF