Maxwell Para Simples Indexação

Título
[pt] TRATAMENTO DE EFLUENTES CONTENDO CIANETO LIVRE ATRAVÉS DO SISTEMA H2O2/UV

Título
[en] TREATMENT OF EFFLUENTS CONTAINING FREE CYANIDE THROUGH THE SYSTEM H2O2/UV

Autor
[pt] ADRIANA CINOPOLI GONCALVES

Vocabulário
[pt] PEROXIDO DE HIDROGENIO

Vocabulário
[pt] RADIACAO ULTRAVIOLETA

Vocabulário
[pt] CIANETO LIVRE

Vocabulário
[pt] TRATAMENTO DE EFLUENTES

Vocabulário
[en] HYDROGEN PEROXIDE

Vocabulário
[en] ULTRAVIOLET RADIATION

Vocabulário
[en] FREE CYANIDE

Vocabulário
[en] EFFLUENT TREATMENT

Resumo
[pt] O presente trabalho teve como objetivo estudar o tratamento de efluentes contendo cianeto livre através do sistema H2O2/UV e selecionar as condições operacionais mais adequadas para uma maior eficiência do processo. Para isso, foram empregadas soluções sintéticas de KCN com características de pH e concentração similares às condições de um efluente industrial real. O fotorreator utilizado nos testes de oxidação foi um reator cilíndrico de seção anular, equipado com uma lâmpada de baixa pressão de 28 W concêntrica com emissão em 254 nm, onde a solução ficava diretamente em contato com a mesma. Este fotorreator foi acoplado a um sistema de refrigeração que mantinha a temperatura de operação em 25oC.As variáveis avaliadas foram concentração inicial de cianeto em solução, pH inicial da solução, potência de UV irradiada e razão molar [H2O2]/[CN-]. Para soluções contendo uma concentração inicial de cianeto igual a 100 ppm, foi possível atingir uma eficiência remoção de 99,9 por cento em 25 minutos, em pH igual a 9,5, com uma razão molar [H2O2]:[CN-] igual a 3. Para efluentes contendo uma concentração inicial de cianeto igual a 300 ppm, nas mesmas condições operacionais, alcançou-se a mesma eficiência em 30 minutos.

Resumo
[en] The present work had the objective of studying the treatment of effluents containing free cyanide through the system H2O2/UV, and of selecting the best operational conditions for best efficiency of the process. For that, it was employed synthetic solutions of KCN with characteristics of pH and concentration similar to those of a real effluent. The photoreactor employed in the oxidation tests was a cylindrical reactor of annular section, equipped with a concentrical low pressure lamp of 28 W with emission in 254 nm, where the solution was in direct contact with the lamp. This photoreactor was coupled with a cooling system which kept the operation temperature at 25oC. The evaluated variables were initial cyanide concentration in solution, initial pH of the solution, power of radiated UV and molar ratio [H2O2]/[CN-]. For solutions containing an initial concentration of cyanide equal to 100 ppm, it was possible to reach a removal efficiency of 99.9 per cent in 25 minutes, in pH equal to 9.5, with a molar ratio of [H2O2]:[CN-] equal to 3. For effluents containing an initial concentration of cyanide equal to 300 ppm, at the same operational conditions, it was possible to achieve the same removal efficiency in 30 minutes.

Orientador(es)
LUIZ ALBERTO CESAR TEIXEIRA

Banca
LUIZ ALBERTO CESAR TEIXEIRA

Banca
FRANCISCO JOSE MOURA

Banca
ROBERTO DE B EMERY TRINDADE

Banca
LIDIA YOKOYAMA

Banca
OSWALDO CALDAS DA CUNHA

Catalogação
2005-03-10

Apresentação
2004-09-08

Tipo
[pt] TEXTO

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=6043@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=6043@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.6043


Arquivos do conteúdo
CAPA, AGRADECIMENTOS, RESUMO, ABSTRACT, SUMÁRIO E LISTAS PDF
CAPÍTULO 1 PDF
CAPÍTULO 2 PDF
CAPÍTULO 3 PDF
CAPÍTULO 4 PDF
CAPÍTULO 5 PDF
CAPÍTULO 6 PDF
CAPÍTULO 7 PDF
CAPÍTULO 8 PDF
REFERÊNCIAS BIBLIOGRÁFICAS E APÊNDICES PDF