Título
[pt] MODELAGEM DE NOVOS SISTEMAS DE REFRIGERAÇÃO COMERCIAIS OPERANDO COM FLUIDOS DE BAIXO GWP
Título
[en] MODELING OF NEW COMMERCIAL REFRIGERATION SYSTEMS OPERATING WITH LOW-GWP FLUIDS
Autor
[pt] RICARDO FERNANDO PAES TIECHER
Vocabulário
[pt] SIMULACAO
Vocabulário
[pt] LCPP
Vocabulário
[pt] FLUIDOS COM BAIXO GWP
Vocabulário
[pt] CO2 TRANSCRITICO
Vocabulário
[pt] SISTEMA SECUNDARIO
Vocabulário
[pt] REFRIGERACAO COMERCIAL
Vocabulário
[pt] CONSUMO DE ENERGIA
Vocabulário
[pt] IMPACTO AMBIENTAL
Vocabulário
[en] SIMULATION
Vocabulário
[en] LCCP
Vocabulário
[en] LOW-GWP FLUIDS
Vocabulário
[en] CO2 BOOSTER
Vocabulário
[en] PUMPED CO2
Vocabulário
[en] COMMERCIAL REFRIGERATION
Vocabulário
[en] ENERGY CONSUMPTION
Vocabulário
[en] ENVIRONMENTAL IMPACT ANALYSIS
Resumo
[pt] Configurações novas e tradicionais de sistemas de refrigeração comerciais foram comparadas considerando sua operação com fluidos refrigerantes alternativos. Primeiramente, desenvolveram-se modelos termodinâmicos para o ciclo transcrítico de dois estágios com refrigerante CO2 (CO2 booster) e para o sistema indireto com CO2 bifásico operando como fluido secundário (pumped CO2). Tais tecnologias foram, em seguida, comparadas com o ciclo de expansão direta (DX) por meio do COP e do consumo anual de energia. Nessa análise, R404A, CO2, e misturas não-azeotrópicas de baixo GWP foram utilizados como
fluidos refrigerantes. Em segundo lugar, desenvolveu-se modelo de parâmetros concentrados para simular a operação em regime permanente do sistema de expansão direta com múltiplos compressores e evaporadores. O método multizona foi utilizado na modelagem dos trocadores de calor tubo-e-aleta, com a consideração de diferentes tipos de aletas e superfícies internas para os tubos. Resultados da simulação foram comparados com dados experimentais e, em seguida, calculou-se o impacto ambiental do sistema operando com diferentes refrigerantes de baixo GWP, por meio da metodologia LCCP.
Resumo
[en] Comparison of new and conventional commercial refrigeration systems, operating with typical and alternative refrigerants, was performed. First, thermodynamic models for the pumped CO2 and the CO2 booster cycles were developed. The COP and the annual energy consumption of these novel designs were compared to those of the traditional direct expansion system in different geographic locations, to take into account year-round climate data. Refrigerant R404A, CO2 and new low-GWP non-azeotropic blends were considered as working uids in this analysis. Second, a component-based lumped parameter model to simulate the steady-state operation of a multicompressor multi-evaporator direct expansion system was developed. The modeling effort considered a multizone approach for the tube-and-fin heat exchangers, as well as addressing enhanced internal surfaces and different fin patterns. Predicted results were compared with experimental data, and a life cycle climate performance (LCCP) analysis was performed to compare the environmental impact of new low-GWP refrigerants.
Orientador(es)
JOSE ALBERTO DOS REIS PARISE
Coorientador(es)
SAMUEL FORTUNATO YANA MOTTA
Banca
JOSE ALBERTO DOS REIS PARISE
Banca
SERGIO LEAL BRAGA
Banca
CARLOS VALOIS MACIEL BRAGA
Banca
ROBERTO DE AGUIAR PEIXOTO
Catalogação
2018-11-07
Apresentação
2014-03-18
Tipo
[pt] TEXTO
Formato
application/pdf
Formato
application/pdf
Formato
application/pdf
Formato
application/pdf
Formato
application/pdf
Formato
application/pdf
Formato
application/pdf
Formato
application/pdf
Formato
application/pdf
Idioma(s)
INGLÊS
Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=35538@1
Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=35538@2
Referência DOI
https://doi.org/10.17771/PUCRio.acad.35538
Arquivos do conteúdo
CAPA, AGRADECIMENTOS, ABSTRACT, RESUMO, SUMÁRIO E LISTAS PDF CAPÍTULO 1 PDF CAPÍTULO 2 PDF CAPÍTULO 4 PDF CAPÍTULO 5 PDF CAPÍTULO 6 PDF CAPÍTULO 7 PDF BIBLIOGRAFIA E APÊNDICES PDF CAPÍTULO 3 PDF