Maxwell Para Simples Indexação

Título
[pt] MODELAGEM DE NOVOS SISTEMAS DE REFRIGERAÇÃO COMERCIAIS OPERANDO COM FLUIDOS DE BAIXO GWP

Título
[en] MODELING OF NEW COMMERCIAL REFRIGERATION SYSTEMS OPERATING WITH LOW-GWP FLUIDS

Autor
[pt] RICARDO FERNANDO PAES TIECHER

Vocabulário
[pt] SIMULACAO

Vocabulário
[pt] LCPP

Vocabulário
[pt] FLUIDOS COM BAIXO GWP

Vocabulário
[pt] CO2 TRANSCRITICO

Vocabulário
[pt] SISTEMA SECUNDARIO

Vocabulário
[pt] REFRIGERACAO COMERCIAL

Vocabulário
[pt] CONSUMO DE ENERGIA

Vocabulário
[pt] IMPACTO AMBIENTAL

Vocabulário
[en] SIMULATION

Vocabulário
[en] LCCP

Vocabulário
[en] LOW-GWP FLUIDS

Vocabulário
[en] CO2 BOOSTER

Vocabulário
[en] PUMPED CO2

Vocabulário
[en] COMMERCIAL REFRIGERATION

Vocabulário
[en] ENERGY CONSUMPTION

Vocabulário
[en] ENVIRONMENTAL IMPACT ANALYSIS

Resumo
[pt] Configurações novas e tradicionais de sistemas de refrigeração comerciais foram comparadas considerando sua operação com fluidos refrigerantes alternativos. Primeiramente, desenvolveram-se modelos termodinâmicos para o ciclo transcrítico de dois estágios com refrigerante CO2 (CO2 booster) e para o sistema indireto com CO2 bifásico operando como fluido secundário (pumped CO2). Tais tecnologias foram, em seguida, comparadas com o ciclo de expansão direta (DX) por meio do COP e do consumo anual de energia. Nessa análise, R404A, CO2, e misturas não-azeotrópicas de baixo GWP foram utilizados como fluidos refrigerantes. Em segundo lugar, desenvolveu-se modelo de parâmetros concentrados para simular a operação em regime permanente do sistema de expansão direta com múltiplos compressores e evaporadores. O método multizona foi utilizado na modelagem dos trocadores de calor tubo-e-aleta, com a consideração de diferentes tipos de aletas e superfícies internas para os tubos. Resultados da simulação foram comparados com dados experimentais e, em seguida, calculou-se o impacto ambiental do sistema operando com diferentes refrigerantes de baixo GWP, por meio da metodologia LCCP.

Resumo
[en] Comparison of new and conventional commercial refrigeration systems, operating with typical and alternative refrigerants, was performed. First, thermodynamic models for the pumped CO2 and the CO2 booster cycles were developed. The COP and the annual energy consumption of these novel designs were compared to those of the traditional direct expansion system in different geographic locations, to take into account year-round climate data. Refrigerant R404A, CO2 and new low-GWP non-azeotropic blends were considered as working uids in this analysis. Second, a component-based lumped parameter model to simulate the steady-state operation of a multicompressor multi-evaporator direct expansion system was developed. The modeling effort considered a multizone approach for the tube-and-fin heat exchangers, as well as addressing enhanced internal surfaces and different fin patterns. Predicted results were compared with experimental data, and a life cycle climate performance (LCCP) analysis was performed to compare the environmental impact of new low-GWP refrigerants.

Orientador(es)
JOSE ALBERTO DOS REIS PARISE

Coorientador(es)
SAMUEL FORTUNATO YANA MOTTA

Banca
JOSE ALBERTO DOS REIS PARISE

Banca
SERGIO LEAL BRAGA

Banca
CARLOS VALOIS MACIEL BRAGA

Banca
ROBERTO DE AGUIAR PEIXOTO

Catalogação
2018-11-07

Apresentação
2014-03-18

Tipo
[pt] TEXTO

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Idioma(s)
INGLÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=35538@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=35538@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.35538


Arquivos do conteúdo
CAPA, AGRADECIMENTOS, ABSTRACT, RESUMO, SUMÁRIO E LISTAS PDF
CAPÍTULO 1 PDF
CAPÍTULO 2 PDF
CAPÍTULO 4 PDF
CAPÍTULO 5 PDF
CAPÍTULO 6 PDF
CAPÍTULO 7 PDF
BIBLIOGRAFIA E APÊNDICES PDF
CAPÍTULO 3 PDF