Maxwell Para Simples Indexação

Título
[en] ANALYSIS OF THE INFLUENCE OF VISCOSITY ON THE PETROLEUM FLOW RATE MEASUREMENT BY ULTRASONIC METERS

Título
[pt] ANÁLISE DA INFLUÊNCIA DA VISCOSIDADE NA MEDIÇÃO DE VAZÃO DE PETRÓLEO POR MEDIDORES ULTRASSÔNICOS

Autor
[pt] WAGNER JOSÉ DOS SANTOS

Vocabulário
[pt] METROLOGIA

Vocabulário
[pt] ALTOSONIC V

Vocabulário
[pt] MEDIDOR ULTRASSONICO

Vocabulário
[pt] VAZAO

Vocabulário
[pt] VISCOSIDADE

Vocabulário
[pt] CALIBRACAO

Vocabulário
[en] METROLOGY

Vocabulário
[en] ALTOSONIC V

Vocabulário
[en] ULTRASONIC FLOWMETER

Vocabulário
[en] FLOW

Vocabulário
[en] VISCOSITY

Vocabulário
[en] CALIBRATION

Resumo
[pt] No Brasil, a medição de petróleo é regulada pela ANP e pelo INMETRO. O Regulamento Técnico de Medição de Petróleo e Gás Natural exige que os medidores de vazão de petróleo sejam calibrados nas condições mais próximas das encontradas no local de medição, tanto para o fluido (massa específica e viscosidade) quanto operacionais (vazão, pressão e temperatura). Replicar todas estas condições nos laboratórios de calibração nacionais é muito complicado e dispendioso. Assim, neste trabalho foram avaliados os comportamentos de 7 medidores Altosonic V calibrados com 5 tipos de fluidos (oural, condensat, fuel, heavy fuel e água). Os fatores de calibração dos medidores foram submetidos a avaliações estatísticas e curvas de calibração foram ajustadas buscando identificar possíveis tendências de comportamento. Após supor-se que vazões e viscosidades teriam influência na aleatoriedade dos fatores, chegou-se à conclusão que, utilizando as calibrações de fábrica (fingerprint) do medidor, que cobrem toda a faixa de viscosidade e vazão de medição com a utilização do número de Reynolds, os limites requeridos por norma de erros para medição fiscal de são atendidos. Assim, sugere-se que as verificações periódicas do Altosonic V sejam feitas com o fluido disponível no laboratório de calibração, observando a coerência dos fatores obtidos nesta calibração e na calibração inicial, buscando o atendimento aos limites legais da aplicação.

Resumo
[en] In Brazil, the measurement of oil is regulated by ANP and INMETRO. The Technical Regulation for Petroleum and Natural Gas requires that the oil flow meters be calibrated in conditions close to those found at the measurement site, both regarding the fluid (density and viscosity) and operational conditions (flow rate, pressure and temperature). It is very difficult to replicate all these conditions in national calibration facilities and expensive too. Thus, this study evaluated the behavior of 7 Altosonic V meters calibrated with 5 types of fluids (oural, condensat, fuel, heavy fuel and water). The calibration factors of the meters were subjected to statistical evaluation and calibration curves were fitted looking for possible behavior trends. Supposing that flow rates and viscosities would influence randomly the factors, a conclusion was reached that, by using the factory meter calibrations (fingerprint), that cover the entire measurement range of viscosity and flow rates, by using Reynolds number, the required by norm fiscal measurement error limits are met. Thus, it is suggested that periodic checks of Altosonic V could be made with the fluid available in the calibration facility, verifying the consistency of the factors obtained in this calibration and in the fingerprint, aimed at complying with the legal limits of the application.

Orientador(es)
ALCIR DE FARO ORLANDO

Coorientador(es)
CARLOS ROBERTO HALL BARBOSA

Banca
ALCIR DE FARO ORLANDO

Banca
CARLOS ROBERTO HALL BARBOSA

Banca
DANIEL RAMOS LOUZADA

Banca
MARIA HELENA FARIAS

Banca
RENATO NUNES TEIXEIRA

Catalogação
2016-11-07

Apresentação
2016-04-20

Tipo
[pt] TEXTO

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=27893@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=27893@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.27893


Arquivos do conteúdo
NA ÍNTEGRA PDF