Título
[pt] AVALIAÇÃO DA UTILIZAÇÃO DE LODO ATIVADO E DO PROCESSO DE OZONIZAÇÃO NA REMEDIAÇÃO DE ÁGUAS SUBTERRÂNEAS ORIUNDAS DE SISTEMAS PUMP AND TREAT

Título
[en] EVALUATION OF ACTIVATED SLUDGE USE AND OZONATION PROCESS IN REMEDIATION OF GROUNDWATER DERIVED FROM PUMP AND TREAT SYSTEMS

Autor
[pt] RAPHAEL GONCALVES RIEBOLDT OLIVEIRA

Vocabulário
[pt] AGUA SUBTERRANEA

Vocabulário
[pt] PUMP AND TREAT

Vocabulário
[pt] PROCESSO COMBINADO

Vocabulário
[pt] LODO ATIVADO

Vocabulário
[pt] AREA CONTAMINADA

Vocabulário
[pt] OZONIO

Vocabulário
[pt] BIODEGRADACAO

Vocabulário
[pt] EFLUENTES

Vocabulário
[pt] OXIDACAO QUIMICA

Vocabulário
[en] GROUNDWATER

Vocabulário
[en] CONTAMINATED AREA

Vocabulário
[en] OZONE

Vocabulário
[en] BIODEGRADATION

Vocabulário
[en] EFFLUENTS

Vocabulário
[en] CHEMICAL OXIDATION

Resumo
[pt] Em função do crescente número de área contaminadas, identificadas nos grandes centros urbanos, é de crucial importância a evolução e o desenvolvimento dos processos relacionados ao tratamento destes locais, visando reduzir os riscos à saúde humana e ao meio ambiente, associados à presença dos contaminantes no meio subterrâneo. A presente dissertação tem como objetivo principal avaliar a eficiência de diferentes técnicas processuais, que poderiam ser aplicadas no tratamento de águas subterrâneas contaminadas, incluindo a ozonização e o uso de lodo ativado. Para isso, foram realizados ensaios de tratabilidade no laboratório do Institute of Sanitary and Environmental Engineering, da Universidade Técnica de Braunschweig, na Alemanha, os quais foram divididos em 3 etapas. A primeira etapa consistiu de um tratamento de caráter biológico, utilizando apenas o lodo ativado, coletado em estações de tratamento de efluentes sanitários, para a degradação de compostos orgânicos presentes em efluentes, artificiais e industriais, que simularam um efluente oriundo de um sistema de tratamento de uma área contaminada. A segunda etapa utilizou como técnica de tratamento, para o mesmo efluente, a ozonização, promovendo assim a oxidação química dos contaminantes. Por fim, foi utilizada uma combinação dos dois processos, sendo realizada a ozonização do efluente antes da degradação biológica. O objetivo desta etapa foi avaliar o incremento da biodegradabilidade do efluente por meio da ozonização. Os resultados obtidos indicaram, além da remoção da cor do efluente, uma efetiva redução dos valores de DQO, quando combinadas as duas técnicas de tratamento, sugerindo que a combinação das mesmas pode ser uma boa alternativa para o tratamento de efluentes de alta complexidade.

Resumo
[en] Given the growing number of contaminated sites identified in large urban areas, it is of crucial importance the evolution and development of treatment processes for these sites, targeting the reduction of environmental and human health risks related to soil and groundwater contamination. The main goal of this dissertation is to evaluate the efficiency of various processing methods that could be applied in the treatment of contaminated groundwater, including the ozonation and activated sludge utilization. For that, jar tests were conducted in the laboratory of Institute of Sanitary and Environmental Engineering, at Braunschweig Technical University, in Germany, in three steps. The first step performed a biological treatment utilizing the activated sludge only which was collected from sewage treatment plants for the biodegradation of organic compounds present in effluents, both artificial and industrial, which simulated the effluent from a contaminated site treatment system. The second step utilized as treatment method, for the same effluent, an ozonation process, promoting the chemical oxidation of the contaminants. At last, a combination of both methods was tested where the ozonation was done prior to the biodegradation. The objective of this step was to evaluate the additional results of the biodegradation of the effluent when an ozonation process is done first. The results showed, in addiction of the color removal from the effluent, a larger reduction of DQO when both techniques are combined, suggesting that the combination can be a good alternative for treatment of high complexity wastewater.

Orientador(es)
JOSE TAVARES ARARUNA JUNIOR

Coorientador(es)
NORBERT DICHTL

Banca
LUIZ ALBERTO CESAR TEIXEIRA

Banca
JOSE TAVARES ARARUNA JUNIOR

Banca
MARIA CLAUDIA BARBOSA

Banca
PATRICIO JOSE MOREIRA PIRES

Catalogação
2016-10-19

Apresentação
2014-09-16

Tipo
[pt] TEXTO

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=27697@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=27697@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.27697


Arquivos do conteúdo
CAPÍTULO 4 PDF
CAPA, AGRADECIMENTOS, RESUMO, ABSTRACT, SUMÁRIO E LISTAS PDF
CAPÍTULO 1 PDF
CAPÍTULO 2 PDF
CAPÍTULO 3 PDF
CAPÍTULO 5 PDF
APÊNDICE PDF