Título: | AUTOMATIC GAS FLOW CONTROLLER | ||||||||||||
Autor(es): |
DIEGO RUSSO JULIANO |
||||||||||||
Colaborador(es): |
SERGIO LEAL BRAGA - Orientador |
||||||||||||
Catalogação: | 16/ABR/2008 | Língua(s): | PORTUGUESE - BRAZIL |
||||||||||
Tipo: | TEXT | Subtipo: | SENIOR PROJECT | ||||||||||
Notas: |
[pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio. [en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio. |
||||||||||||
Referência(s): |
[pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/TFCs/consultas/conteudo.php?strSecao=resultado&nrSeq=11555@1 [en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/TFCs/consultas/conteudo.php?strSecao=resultado&nrSeq=11555@2 |
||||||||||||
DOI: | https://doi.org/10.17771/PUCRio.acad.11555 | ||||||||||||
Resumo: | |||||||||||||
This paper s objective is to present a sonic flow
controller and meter system, developed
at the PUC-Rio s Vehicular Engineering Laboratory, to
explain how it works and to analyze data
obtained through experiment.
The system can be divided into two parts, the mechanical
and the electronic (hardware
and software), that interact through pressure and
temperature transducers and a data acquisition
board. This way the mechanical part can be changed or
repositioned in real time, depending on
the necessity of increasing or decreasing the flow.
The gas flow control is made by the movement of a conic
needle, which blocks partially
the nozzle s cross section area. The needle s movement is
provided by a step motor connected to
the computer.
The experiment was divided in two phases: in the first, the
flow controller was
calibrated and then, in the second one, the system was
tested individually, actuating directly on a
compressed air flow.
The flow meter and controller system reacted as expected
during the experiment,
returning results witch were consonant to the expectations.
Therefore the equipment was
considered functional and proved to be largely applicable
in several industry sectors.
|
|||||||||||||
|