Título: | METROLOGICAL ANALYSIS OF THE TRANSIENT BEHAVIOR OF A WET BULB AND DRY BULB PSYCHROMETER | ||||||||||||||||||||||||||||||||||||
Autor: |
FRANKY EDUARDO REYES CAC |
||||||||||||||||||||||||||||||||||||
Colaborador(es): |
ALCIR DE FARO ORLANDO - Orientador |
||||||||||||||||||||||||||||||||||||
Catalogação: | 29/JUL/2005 | Língua(s): | PORTUGUESE - BRAZIL |
||||||||||||||||||||||||||||||||||
Tipo: | TEXT | Subtipo: | THESIS | ||||||||||||||||||||||||||||||||||
Notas: |
[pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio. [en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio. |
||||||||||||||||||||||||||||||||||||
Referência(s): |
[pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=6718&idi=1 [en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=6718&idi=2 |
||||||||||||||||||||||||||||||||||||
DOI: | https://doi.org/10.17771/PUCRio.acad.6718 | ||||||||||||||||||||||||||||||||||||
Resumo: | |||||||||||||||||||||||||||||||||||||
This work presents a study of the transient behavior of a
wet bulb and dry bulb
psychrometer, as well as the determination of the humidity
of air under different environment
conditions. The wet bulb and dry bulb psychrometer are
widely used in the air conditioning
industry, for monitoring the humidity in closed
environments, and in meteorology stations for
the monitoring the atmosphere humidity and in the
prevention of the climatic conditions. For the
development of the present work, a wet bulb and dry bulb
aspirated psychrometer was built,
using two thermometers, which are physically separated by
an acrylic plate. Two types of
thermometers were used: PT-100 and Thermocouple. In the
evaluation of the humidity content,
the measurement of temperature was been registered by two
thermometers (used as the
psychrometer components), where one of them registers the
temperature of the air that impacts
the psychrometer and serves as reference; and the other
one covered by a wick wet with distilled
water, registers a lower temperature due to the phenomenon
of evaporative cooling, which is a
consequence of the mass transfer between the wet wick and
the air that is forced to pass through
it. In the evaluation of the transient behavior of the
psychrometer different models of adjustment
to the experimental data have been applied, seeking the
best theoretical model that represented
the behaviour through the time of the humid bulb
thermometer. Among the adjustment models
are: the linear one, the exponential one, the addition of
two exponential ones, the rational one,
polynomial of exponential degree 6 and the linear one
(which adds the exponential curve and the
straight line). For each of the models the method of the
minimum square had been applied, and
it was found by means of the of Aikaike´s criterion that
the linear exponential model is the best
one. The uncertainties of the constants of the different
models of adjustment were calculated
through the method of the finite differences. The values
of the time constants of time for
different values of air speed and different degrees of
humidity for both thermometers PT-100
and Thermocouple type had been presented. Finally, the
results of the application of the
multiple linear regression are presented among the time
constants, the speed, and the humidity
of air for both psychrometer based on the thermometers PT-
100 type and the thermometers
Thermocouple type. This MSc research contributes towards
the development of the thermal
metrology in Brazil.
|
|||||||||||||||||||||||||||||||||||||
|