Logo PUC-Rio Logo Maxwell
ETDs @PUC-Rio
Consulta aos Conteúdos
Título: AUTOCALIBRATION OF FREQUENCY STANDARDS USING THE INTERNET
Autor: DALTON VILELA CAMILHER
Colaborador(es): FERNANDO LAZARO FREIRE JUNIOR - Orientador
IVAN MOURILHE SILVA - Orientador
Catalogação: 10/OUT/2001 Língua(s): PORTUGUESE - BRAZIL
Tipo: TEXT Subtipo: THESIS
Notas: [pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio.
[en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio.
Referência(s): [pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=2015@1
[en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=2015@2
[es] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=2015@4
DOI: https://doi.org/10.17771/PUCRio.acad.2015
Resumo:
The time and frequency calibration of atomic standards presents the inconvenience of the need of transportation of the Transfer Standard to the laboratories in which stay the standards to be calibrate. This happens because the laboratories do not possess a way to send its standards to the Departamento do Serviço da Hora do Observatório Nacional (DSH/ON), organ representative of INMETRO in Time and Frequency calibrations and detainer of the National Standard. This work intends the substitution of the procedure adopted today by a system of automatic calibration using Internet, eliminating the need of the displacement of the Transfer Standard. In this new procedure, the reference is t he Global Position Sistem (GPS) receiver, assuming the role of the Transfer Standard, to which the standard to be calibrate is compared continuosly. The access and storage of the data for the DSH/ON are made by means of a computer code that remotely controls the calibration through an Internet connection. The present work involves a comparison among both systems, the whole development and presentation of the computer code, the assembling of a complete system of practical simulation, the acquisition and data treatment and the presentation of the procedure used to obtain the measurement of the uncertainty. The advantage of an automatic calibration system, as well as of the collection of the data, is the fact that it not depending of the transportation of the Reference Standard for the accomplishment of the calibratio. As a conclusion of this work the obtained uncertainty is compared with the one in use today and based in this comparison we made considerations about the implementation of the new system and the use of the GPS receiver as Transfer Standard.
Descrição: Arquivo:   
PDF      
PDF      
PDF      
PDF