Logo PUC-Rio Logo Maxwell
ETDs @PUC-Rio
Estatística
Título: METHODS FOR THE IMIDACLOPRID QUANTIFICATION IN AQUEOUS SOLUTIONS: METROLOGICAL VALIDATION AND COMPARISON BETWEEN UV-VIS SPECTROPHOTOMETRY AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
Autor: KELLY NEOOB DE CARVALHO CASTRO
Colaborador(es): REINALDO CALIXTO DE CAMPOS - Orientador
RICARDO QUEIROZ AUCELIO - Coorientador
Catalogação: 21/MAI/2007 Língua(s): PORTUGUESE - BRAZIL
Tipo: TEXT Subtipo: THESIS
Notas: [pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio.
[en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio.
Referência(s): [pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=9960&idi=1
[en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=9960&idi=2
DOI: https://doi.org/10.17771/PUCRio.acad.9960
Resumo:
Fit for purpose analytical procedures must be sufficiently reliable to support any decision taken based on the generated results. In order to achieve that, consolidated adequacy evaluation of the analytical procedure must be obtained by performing validation experiments. In this work, an alternative and simpler spectrophotometric method for the quantification of imidacloprid in aqueous samples was compared to the HPLC-UV based reference method used in routine. The overall validation procedure started with a detailed description of each validation stage, followed by the settling of the limits for each of the validation parameters and then, applying the following statistical techniques to evaluate each of the parameters: ANOVA, regression analysis, significance tests, control charts and uncertainty estimation. The measurement of uncertainties estimation, based on ISO-GUM recommendations, was done for both analytical procedures (the alternative one and the reference one). After comparing these uncertainties with the tolerance values, the adequacy of the alternative proposed procedure was confirmed. Finally, by consolidating the validation, the experimental comparison of quantification methods was conducted. Besides evaluating the analytical procedure for trace-level imidacloprid quantification in water samples, the proposed method was also evaluated as the analytical procedure for imidacloprid based formulated products. In this case, it was demonstrated that the spectrophotometric method did not present the requested metrological requirements for such application, since the estimated uncertainties of the alternative procedure were about 50 % of the tolerance values.
Descrição: Arquivo:   
COVER, ACKNOWLEDGEMENTS, RESUMO, ABSTRACT, SUMMARY AND LISTS PDF    
CHAPTER 1 PDF    
CHAPTER 2 PDF    
CHAPTER 3 PDF    
CHAPTER 4 PDF    
CHAPTER 5 PDF    
REFERENCES AND APPENDICES PDF