Título: | DESIGN OF EXPERIMENTS FOR METROLOGICAL OPTIMIZATION AND RELIABILITY OF A NEW PH MEASUREMENT SYSTEM IN HYDRATED FUEL ETHANOL | ||||||||||||
Autor: |
NATALIA CAMBIAGHI ATILIO |
||||||||||||
Colaborador(es): |
ELCIO CRUZ DE OLIVEIRA - Orientador FERNANDO LUIS FERTONANI - Coorientador |
||||||||||||
Catalogação: | 08/NOV/2022 | Língua(s): | PORTUGUESE - BRAZIL |
||||||||||
Tipo: | TEXT | Subtipo: | THESIS | ||||||||||
Notas: |
[pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio. [en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio. |
||||||||||||
Referência(s): |
[pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=61139&idi=1 [en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=61139&idi=2 |
||||||||||||
DOI: | https://doi.org/10.17771/PUCRio.acad.61139 | ||||||||||||
Resumo: | |||||||||||||
The pH is one of the quality control parameters of fuel ethanol, established by the
Brazilian standard ABNT NBR 10891, whose scope is specific for hydrated fuel
ethanol, and by the American standard ASTM D 6423, which focuses on anhydrous
ethanol fuel. In this context, the present study presents a critical analysis of the
composition of the electrodes used by the different measurement systems for
ethanol pH, due to the presence of water in the composition of the glass electrode.
Thus, the objective of the present study was to propose a new system for measuring
the pH of hydrated fuel ethanol, which was the only solvent used, using acid-base
indicators as a reference. Box-Behnken Design made possible to determine the
optimal condition expected for the new measurement system, which was compared
with the systems proposed by the normative references and later with the pH range
defined by the indicators. The results revealed that the pH values obtained by the
different systems used, including the one proposed by the present study, are
statistically different from each other, and that only the values obtained by the new
measurement system are suitable for the pH range found by the indicators. The
optimized electrode presented an adequate response sensitivity to the Nernst
equation, having an operational behavior adequate to the new measurement system
proposed by the present study.
|
|||||||||||||
|