Título: | TREATMENT OF EFFLUENTS CONTAINING FREE CYANIDE THROUGH THE SYSTEM H2O2/UV | |||||||
Autor: |
ADRIANA CINOPOLI GONCALVES |
|||||||
Colaborador(es): |
LUIZ ALBERTO CESAR TEIXEIRA - Orientador |
|||||||
Catalogação: | 10/MAR/2005 | Língua(s): | PORTUGUESE - BRAZIL |
|||||
Tipo: | TEXT | Subtipo: | THESIS | |||||
Notas: |
[pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio. [en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio. |
|||||||
Referência(s): |
[pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=6043&idi=1 [en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=6043&idi=2 |
|||||||
DOI: | https://doi.org/10.17771/PUCRio.acad.6043 | |||||||
Resumo: | ||||||||
The present work had the objective of studying the
treatment of effluents containing free cyanide through the
system H2O2/UV, and of selecting the best operational
conditions for best efficiency of the process. For that, it
was employed synthetic solutions of KCN with
characteristics of pH and concentration similar to those of
a real effluent. The photoreactor employed in the oxidation
tests was a cylindrical reactor of annular section,
equipped with a concentrical low pressure lamp of 28 W with
emission in 254 nm, where the solution was in direct
contact with the lamp. This photoreactor was coupled with a
cooling system which kept the operation temperature at
25oC. The evaluated variables were initial cyanide
concentration in solution, initial pH of the solution,
power of radiated UV and molar ratio [H2O2]/[CN-]. For
solutions containing an initial concentration of cyanide
equal to 100 ppm, it was possible to reach a removal
efficiency of 99.9 per cent in 25 minutes, in pH equal to 9.5, with
a molar ratio of [H2O2]:[CN-] equal to 3. For effluents
containing an initial concentration of cyanide equal to 300
ppm, at the same operational conditions, it was possible to
achieve the same removal efficiency in 30 minutes.
|
||||||||