Título: | THE EFFECT OF SURFACE ON NITI FILES SUBJECTED TO TORSION LOADING | |||||||
Autor: |
JULIO CESAR DE AZEVEDO CARVALHAL |
|||||||
Colaborador(es): |
IVANI DE SOUZA BOTT - Orientador CARLOS NELSON ELIAS - Coorientador |
|||||||
Catalogação: | 10/FEV/2005 | Língua(s): | PORTUGUESE - BRAZIL |
|||||
Tipo: | TEXT | Subtipo: | THESIS | |||||
Notas: |
[pt] Todos os dados constantes dos documentos são de inteira responsabilidade de seus autores. Os dados utilizados nas descrições dos documentos estão em conformidade com os sistemas da administração da PUC-Rio. [en] All data contained in the documents are the sole responsibility of the authors. The data used in the descriptions of the documents are in conformity with the systems of the administration of PUC-Rio. |
|||||||
Referência(s): |
[pt] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=5920&idi=1 [en] https://www.maxwell.vrac.puc-rio.br/projetosEspeciais/ETDs/consultas/conteudo.php?strSecao=resultado&nrSeq=5920&idi=2 |
|||||||
DOI: | https://doi.org/10.17771/PUCRio.acad.5920 | |||||||
Resumo: | ||||||||
NiTi Profile® 25/.04 files do not undergo surface
polishing treatments after machining, and therefore
exhibit local stress concentrators and, consequently,
areas of cracking and fractures. The effect of different
surface conditions on the torsional strength of endodontic
files were evaluated. 18 NiTi Profile® 25/.04 rotary files
were examined by scanning electron. A group of 6 files
(Group I) were not subjected to any chemical treatment,
another group of 6 (Group II) were treated for 2 minutes
using a solution of 8% Nitric Acid, 4% Flouridic Acid, and
a further 6 (Group III) were treated with the same
solution fot 2.5 minutes. All the file, with and without
treatment, were loaded in a torsion test and fractography
of the samples was undertaken by scanning electron
microscopy. The variables investigated were, torque at
fracture and maximum angle of rotation at fracture. The
results obtained in these mechanical tests were subjected
to a statistical analysis utilizing the T-Student test. It
can be concluded from these results that there was a
statistically significant difference between the maximum
torque results for groups II and III, and between the
maximum angle results for groups I and III.
|
||||||||