[en] METHODS FOR THE IMIDACLOPRID QUANTIFICATION IN AQUEOUS SOLUTIONS: METROLOGICAL VALIDATION AND COMPARISON BETWEEN UV-VIS SPECTROPHOTOMETRY AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

Título
[pt] MÉTODOS DE QUANTIFICAÇÃO DE IMIDACLOPRID EM SOLUÇÕES AQUOSAS: VALIDAÇÃO METROLÓGICA E COMPARAÇÃO ENTRE ABSORCIOMETRIA MOLECULAR E CROMATOGRAFIA LÍQUIDA DE ALTA EFICIÊNCIA

Autor
[pt] KELLY NEOOB DE CARVALHO CASTRO

Vocabulário
[pt] METROLOGIA

Vocabulário
[pt] IMIDACLOPRID

Vocabulário
[pt] METODOS ESTATISTICOS

Vocabulário
[pt] VALIDACAO DE METODOS ANALITICOS

Vocabulário
[pt] INCERTEZA DE MEDICAO

Vocabulário
[en] METROLOGY

Vocabulário
[en] IMIDACLOPRID

Vocabulário
[en] STATISTICAL METHODS

Vocabulário
[en] VALIDATION OF ANALYTICAL METHODS

Vocabulário
[en] UNCERTAINTY OF OF MEASUREMENT

Resumo
[pt] Um procedimento analítico é considerado apropriado para uma aplicação específica quando é capaz de gerar resultados confiáveis, que possibilitem a tomada de decisão com grau de confiança adequado, sendo sua adequação consolidada mediante a realização de ensaios de validação. Este trabalho propõe a utilização de um procedimento analítico alternativo, mais simples e econômico, baseado na técnica espectrofotométrica de absorção molecular, para quantificação de imidacloprid, um inseticida sistêmico, em amostras de solução aquosa. Foi demonstrado que o procedimento proposto é adequado ao uso pretendido descrevendo-se, detalhadamente, cada etapa da validação, considerando-se os limites estabelecidos para cada parâmetro de validação e aplicando-se técnicas estatísticas apropriadas na avaliação dos mesmos: análise de variância, análise de regressão, testes de significância, gráficos de controle e a estimativa da incerteza de medição. As incertezas de medição dos procedimentos de rotina e alternativo foram estimadas e comparadas às tolerâncias estipuladas, estabelecendo o procedimento alternativo como adequado. Uma comparação experimental deste procedimento com o de rotina (baseado em HPLC) foi realizada como parte do protocolo de validação. Além da avaliação do procedimento para quantificação de imidacloprid em nível de traços, foi investigada também a possibilidade de sua utilização, para a quantificação do mesmo ingrediente ativo em produtos formulados. Neste caso, foi demonstrado, através da comparação das incertezas estimadas às tolerâncias estabelecidas, que o procedimento alternativo não é adequado, por apresentar incertezas na ordem de aproximadamente 50% do valor destas tolerâncias, não possuindo assim o rigor metrológico requerido para esta aplicação.

Resumo
[en] Fit for purpose analytical procedures must be sufficiently reliable to support any decision taken based on the generated results. In order to achieve that, consolidated adequacy evaluation of the analytical procedure must be obtained by performing validation experiments. In this work, an alternative and simpler spectrophotometric method for the quantification of imidacloprid in aqueous samples was compared to the HPLC-UV based reference method used in routine. The overall validation procedure started with a detailed description of each validation stage, followed by the settling of the limits for each of the validation parameters and then, applying the following statistical techniques to evaluate each of the parameters: ANOVA, regression analysis, significance tests, control charts and uncertainty estimation. The measurement of uncertainties estimation, based on ISO-GUM recommendations, was done for both analytical procedures (the alternative one and the reference one). After comparing these uncertainties with the tolerance values, the adequacy of the alternative proposed procedure was confirmed. Finally, by consolidating the validation, the experimental comparison of quantification methods was conducted. Besides evaluating the analytical procedure for trace-level imidacloprid quantification in water samples, the proposed method was also evaluated as the analytical procedure for imidacloprid based formulated products. In this case, it was demonstrated that the spectrophotometric method did not present the requested metrological requirements for such application, since the estimated uncertainties of the alternative procedure were about 50 % of the tolerance values.

Orientador(es)
REINALDO CALIXTO DE CAMPOS

Coorientador(es)
RICARDO QUEIROZ AUCELIO

Banca
REINALDO CALIXTO DE CAMPOS

Banca
RICARDO QUEIROZ AUCELIO

Banca
JOSINO COSTA MOREIRA

Banca
VANDERLEIA DE SOUZA

Banca
ADERVAL SEVERINO LUNA

Catalogação
2007-05-21

Apresentação
2007-03-30

Tipo
[pt] TEXTO

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=9960@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=9960@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.9960


Arquivos do conteúdo
CAPA, AGRADECIMENTOS, RESUMO, ABSTRACT, SUMÁRIO E LISTAS PDF
CAPÍTULO 1 PDF
CAPÍTULO 2 PDF
CAPÍTULO 3 PDF
CAPÍTULO 4 PDF
CAPÍTULO 5 PDF
REFERÊNCIAS BIBLIOGRÁFICAS E APÊNDICES PDF