Maxwell Para Simples Indexação

Título
[pt] RESISTÊNCIA À TRAÇÃO DE UM SISTEMA DE ANCORAGEM EMBUTIDO EM CONCRETO SUJEITO A CARGA DE IMPACTO

Título
[en] TENSILE STRENGTH OF A CONCRETE ANCHORING SUBJECTED TO IMPACT LOAD

Autor
[pt] JOAQUIM NUNES MARTINS JUNIOR

Vocabulário
[pt] CONCRETO

Vocabulário
[pt] CARGA DE IMPACTO

Vocabulário
[pt] SISTEMAS DE ANCORAGEM

Vocabulário
[pt] CHUMBADOR

Vocabulário
[pt] RESISTENCIA A TRACAO

Vocabulário
[en] CONCRETE

Vocabulário
[en] IMPACT LOAD

Vocabulário
[en] MOORING SYSTEMS

Vocabulário
[en] FASTENERS

Vocabulário
[en] TENSILE STRENGTH

Resumo
[pt] Este trabalho tem como objetivo estudar a resistência de um sistema de ancoragem composto de pinos com cabeça embutidos no concreto, quando submetidos a cargas de impacto. A variável adotada foi a taxa de carregamento cujos valores mínimo e máximo foram 0,015 kN/s (estático) e 54.885 kN/s, respectivamente. O sistema de ancoragem foi projetado de forma que a ruptura fosse governada pelo arrancamento do cone de ruptura. Foram ensaiados onze blocos de concreto com um pino embutido no concreto, sujeitos a diferentes taxas de aplicação de carga. Foram também ensaiados quinze corpos-de-prova de concreto à compressão diametral e nove pinos à tração, também sujeitos a diferentes taxas de aplicação de carga. O objetivo desses ensaios foi verificar a influência da taxa de carregamento sobre as resistências dos materiais - concreto e aço - que participam do sistema de ancoragem. Os resultados mostraram que a área da superfície e a inclinação do cone de ruptura não sofrem grandes alterações. A carga de ruptura do cone de concreto cresce com a taxa de carregamento, e que esse crescimento pode ser descrito por uma função logarítmica. O mesmo foi observado para a resistência à tração do concreto por compressão diametral e para os pinos.

Resumo
[en] This work investigates the strength of a concrete anchor system constituted of headed studs embedded in concrete subjected to impact tension load. The main variable was the loading rate which varied from a minimum of 0,015 kN/s (static) to a maximum of 54885 kN/s. The anchor system was designed so that the failure was governed by concrete cone breakout. Eleven concrete blocks with a single headed stud were tested under different loading rates. In addition, fifteen concrete cylinders subjected to compression along a diameter (split cylinder test) and nine headed studs subjected to tension were tested under different loading rates in order to investigate the effects of the loading rate on the strength of concrete and steel separately. The results showed that the area and the angle of the concrete cone were not affected by the loading rate. The failure load of the concrete cone increases as the loading rate increases and this phenomenon can be described by a logarithmic function. The concrete split tensile strength and the steel tensile strength also increase as the loading rate increases.

Orientador(es)
GIUSEPPE BARBOSA GUIMARAES

Coorientador(es)
PAULO BATISTA GONCALVES

Banca
RAUL ROSAS E SILVA

Banca
PAULO BATISTA GONCALVES

Banca
GIUSEPPE BARBOSA GUIMARAES

Banca
EMIL DE SOUZA SANCHEZ FILHO

Banca
RONALDO BARROS GOMES

Catalogação
2006-07-24

Apresentação
2006-01-23

Tipo
[pt] TEXTO

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=8724@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=8724@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.8724


Arquivos do conteúdo
CAPA, AGRADECIMENTOS, RESUMO, ABSTRACT, SUMÁRIO E LISTAS PDF
CAPÍTULO 1 PDF
CAPÍTULO 2 PDF
CAPÍTULO 3 PDF
CAPÍTULO 4 PDF
CAPÍTULO 5 PDF
REFERÊNCIAS BIBLIOGRÁFICAS E ANEXOS PDF