[pt] ESTABILIDADE E DEGRADAÇÃO TÉRMICA DE TUBOS DE POLIETILENO FOTO-RETICULADO PARA APLICAÇÃO EM ARMA ZENAMENTO DE ENERGIA GEOTÉRMICA
Título
[en] STABILITY AND THERMAL DEGRADATION OF PHOTO-CROSSLINKED POLYETHYLENE PIPES FOR GEOTHERMAL ENERGY STORAGE APPLICATIONS
Autor
[pt] GIULIA SIMAO BARRETO DE SOUSA
Vocabulário
[pt] POLIETILENO CURADO POR UV
Vocabulário
[pt] MASSA MOLAR ENTRE RETICULACOES
Vocabulário
[pt] RMN ESTATICA DE PROTONS
Vocabulário
[pt] RMN DE ANGULO MAGICO GIRATORIO
Vocabulário
[pt] RMN EM ESTADO SOLIDO
Vocabulário
[pt] DEGRADACAO DO POLIETILENO
Vocabulário
[en] UV CURED POLYETHYLENE
Vocabulário
[en] MOLECULAR WEIGHT BETWEEN CROSSLINKS
Vocabulário
[en] 1H STATIC NMR
Vocabulário
[en] MAGIC SPINNING ANGLE NMR
Vocabulário
[en] SOLID STATE NMR
Vocabulário
[en] POLYETHYLENE DEGRADATION
Resumo
[pt] Este estudo avalia a degradação e a estabilidade de tubos de polietileno reticulado (PEX) projetados para sistemas de armazenamento de energia geotérmica em poços (borehole thermal energy storage- BTES). O foco principal é dado a um novo tipo de tubo PEX, fabricado por meio de um processo de reticulação fotoinduzida (PEX-e). Foram analisadas duas formulações desse material, PEX-e1 e PEX-e2, comparando-as com tubos comerciais de polietileno reticulado por peróxido (PEX-a) e de polietileno bimodal não reticulado (PE100). Na primeira etapa, os tubos foram caracterizados em sua condição como recebidos, a fim de investigar a morfologia e as propriedades após o processamento. O grau de reticulação foi avaliado por meio do teor de gel, enquanto a densidade de reticulação foi determinada utilizando análise mecânica dinâmica (DMA). A composição das fases e a mobilidade molecular foram examinadas por ressonância magnética nuclear (RMN) de prótons e calorimetria exploratória diferencial (DSC), enquanto a estabilidade oxidativa foi medida pelo tempo de indução de oxidação (OIT). Ambas as formulações PEX-e apresentaram elevado grau de reticulação e altos valores de OIT. Na segunda etapa, foi feita uma análise detalhada do envelhecimento de longo prazo. Para isso, os tubos foram submetidos a imersão em água na temperatura de serviço dos sistemas por 210 dias. Alterações nas propriedades foram monitoradas por técnicas como espectroscopia no infravermelho por transformada de Fourier (FTIR), RMN de prótons e carbono-13, colorimetria e DMA. Os resultados indicaram que o envelhecimento físico predominou nos primeiros 30 dias, enquanto, ao longo do tempo, a cisão de cadeias tornou-se o principal mecanismo de degradação. Apesar dos altos níveis iniciais de OIT, ambos os tubos PEX-e apresentaram declínio acelerado de antioxidantes após exposição prolongada. Esses achados ressaltam a necessidade de otimização das formulações PEX-e para melhorar sua estabilidade e durabilidade em aplicações BTES de alta temperatura.
Resumo
[en] This study provides a comprehensive evaluation of the degradation
and stability of crosslinked polyethylene (PEX) pipes designed for high
temperature borehole thermal energy storage (BTES) systems. Special at
tention is given to a novel type of PEX pipe manufactured using a photo
initiated crosslinking (PEX-e) process. Two formulations, PEX-e1 and PEX-e2,
were assessed and compared with commercial peroxide-crosslinked polyethy
lene (PEX-a) and non-crosslinked bimodal polyethylene (PE100) pipes. The
first phase of the study focused on the characterization of the pipes in their
as-received condition to evaluate their morphology and properties post
processing. The degree of crosslinking was quantified through gel content and
the crosslink density was determined through dynamic mechanical analysis
(DMA). Phase composition and molecular mobility were examined using sta
tic 1H nuclear magnetic resonance (NMR) and differential scanning calorimetry
(DSC), while oxidative stability was evaluated using oxidation induction time
(OIT) measurements. Both PEX-e formulations exhibited elevated crosslin
king degrees and high OIT values. The second phase of the study involved a
detailed analysis of thermo-oxidative degradation and stability through ageing
tests. This was achieved by immersing pipes in water at BTES service tem
peratures for 210 days. Changes were monitored using advanced analytical
techniques, including fourier transform infrared spectroscopy (FTIR), 1H and
13C NMR, colorimetry, and DMA. Results revealed that physical ageing do
minated the first 30 days, while over time, chain scission was identified as the
primary degradation mechanism, with PEX-a being the most severely affected.
Interestingly, despite the high OIT levels, both PEX-e exhibit accelerated AO
depletion during prolonged exposure to hot water. These findings highlight the
importance of long-term ageing tests at service conditions and underscore the
need for further optimization of PEX-e formulations specifically tailored for
BTES service conditions.
Orientador(es)
JOSE ROBERTO MORAES D ALMEIDA
Coorientador(es)
MIKAEL SKRIFVARS
Banca
MARCOS HENRIQUE DE PINHO MAURICIO
Banca
JOSE ROBERTO MORAES D ALMEIDA
Banca
LAURA HECKER DE CARVALHO
Banca
MARYSILVIA FERREIRA DA COSTA
Banca
MIKAEL SKRIFVARS
Banca
SUNIL KUMAR LINDSTRöM RAMAMOORTHY
Catalogação
2025-04-03
Apresentação
2025-02-27
Tipo
[pt] TEXTO
Formato
application/pdf
Idioma(s)
INGLÊS
Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=69813@1
Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=69813@2
Referência DOI
https://doi.org/10.17771/PUCRio.acad.69813
Arquivos do conteúdo
NA ÍNTEGRA PDF