Maxwell Para Simples Indexação

Título
[pt] ESTABILIDADE E DEGRADAÇÃO TÉRMICA DE TUBOS DE POLIETILENO FOTO-RETICULADO PARA APLICAÇÃO EM ARMA ZENAMENTO DE ENERGIA GEOTÉRMICA

Título
[en] STABILITY AND THERMAL DEGRADATION OF PHOTO-CROSSLINKED POLYETHYLENE PIPES FOR GEOTHERMAL ENERGY STORAGE APPLICATIONS

Autor
[pt] GIULIA SIMAO BARRETO DE SOUSA

Vocabulário
[pt] POLIETILENO CURADO POR UV

Vocabulário
[pt] MASSA MOLAR ENTRE RETICULACOES

Vocabulário
[pt] RMN ESTATICA DE PROTONS

Vocabulário
[pt] RMN DE ANGULO MAGICO GIRATORIO

Vocabulário
[pt] RMN EM ESTADO SOLIDO

Vocabulário
[pt] DEGRADACAO DO POLIETILENO

Vocabulário
[en] UV CURED POLYETHYLENE

Vocabulário
[en] MOLECULAR WEIGHT BETWEEN CROSSLINKS

Vocabulário
[en] 1H STATIC NMR

Vocabulário
[en] MAGIC SPINNING ANGLE NMR

Vocabulário
[en] SOLID STATE NMR

Vocabulário
[en] POLYETHYLENE DEGRADATION

Resumo
[pt] Este estudo avalia a degradação e a estabilidade de tubos de polietileno reticulado (PEX) projetados para sistemas de armazenamento de energia geotérmica em poços (borehole thermal energy storage- BTES). O foco principal é dado a um novo tipo de tubo PEX, fabricado por meio de um processo de reticulação fotoinduzida (PEX-e). Foram analisadas duas formulações desse material, PEX-e1 e PEX-e2, comparando-as com tubos comerciais de polietileno reticulado por peróxido (PEX-a) e de polietileno bimodal não reticulado (PE100). Na primeira etapa, os tubos foram caracterizados em sua condição como recebidos, a fim de investigar a morfologia e as propriedades após o processamento. O grau de reticulação foi avaliado por meio do teor de gel, enquanto a densidade de reticulação foi determinada utilizando análise mecânica dinâmica (DMA). A composição das fases e a mobilidade molecular foram examinadas por ressonância magnética nuclear (RMN) de prótons e calorimetria exploratória diferencial (DSC), enquanto a estabilidade oxidativa foi medida pelo tempo de indução de oxidação (OIT). Ambas as formulações PEX-e apresentaram elevado grau de reticulação e altos valores de OIT. Na segunda etapa, foi feita uma análise detalhada do envelhecimento de longo prazo. Para isso, os tubos foram submetidos a imersão em água na temperatura de serviço dos sistemas por 210 dias. Alterações nas propriedades foram monitoradas por técnicas como espectroscopia no infravermelho por transformada de Fourier (FTIR), RMN de prótons e carbono-13, colorimetria e DMA. Os resultados indicaram que o envelhecimento físico predominou nos primeiros 30 dias, enquanto, ao longo do tempo, a cisão de cadeias tornou-se o principal mecanismo de degradação. Apesar dos altos níveis iniciais de OIT, ambos os tubos PEX-e apresentaram declínio acelerado de antioxidantes após exposição prolongada. Esses achados ressaltam a necessidade de otimização das formulações PEX-e para melhorar sua estabilidade e durabilidade em aplicações BTES de alta temperatura.

Resumo
[en] This study provides a comprehensive evaluation of the degradation and stability of crosslinked polyethylene (PEX) pipes designed for high temperature borehole thermal energy storage (BTES) systems. Special at tention is given to a novel type of PEX pipe manufactured using a photo initiated crosslinking (PEX-e) process. Two formulations, PEX-e1 and PEX-e2, were assessed and compared with commercial peroxide-crosslinked polyethy lene (PEX-a) and non-crosslinked bimodal polyethylene (PE100) pipes. The first phase of the study focused on the characterization of the pipes in their as-received condition to evaluate their morphology and properties post processing. The degree of crosslinking was quantified through gel content and the crosslink density was determined through dynamic mechanical analysis (DMA). Phase composition and molecular mobility were examined using sta tic 1H nuclear magnetic resonance (NMR) and differential scanning calorimetry (DSC), while oxidative stability was evaluated using oxidation induction time (OIT) measurements. Both PEX-e formulations exhibited elevated crosslin king degrees and high OIT values. The second phase of the study involved a detailed analysis of thermo-oxidative degradation and stability through ageing tests. This was achieved by immersing pipes in water at BTES service tem peratures for 210 days. Changes were monitored using advanced analytical techniques, including fourier transform infrared spectroscopy (FTIR), 1H and 13C NMR, colorimetry, and DMA. Results revealed that physical ageing do minated the first 30 days, while over time, chain scission was identified as the primary degradation mechanism, with PEX-a being the most severely affected. Interestingly, despite the high OIT levels, both PEX-e exhibit accelerated AO depletion during prolonged exposure to hot water. These findings highlight the importance of long-term ageing tests at service conditions and underscore the need for further optimization of PEX-e formulations specifically tailored for BTES service conditions.

Orientador(es)
JOSE ROBERTO MORAES D ALMEIDA

Coorientador(es)
MIKAEL SKRIFVARS

Banca
MARCOS HENRIQUE DE PINHO MAURICIO

Banca
JOSE ROBERTO MORAES D ALMEIDA

Banca
LAURA HECKER DE CARVALHO

Banca
MARYSILVIA FERREIRA DA COSTA

Banca
MIKAEL SKRIFVARS

Banca
SUNIL KUMAR LINDSTRöM RAMAMOORTHY

Catalogação
2025-04-03

Apresentação
2025-02-27

Tipo
[pt] TEXTO

Formato
application/pdf

Idioma(s)
INGLÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=69813@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=69813@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.69813


Arquivos do conteúdo
NA ÍNTEGRA PDF