Maxwell Para Simples Indexação

Título
[pt] ESTUDO DA QUALIDADE DO AR NO INTERIOR DE COZINHAS QUE CONSOMEM LENHA PARA COCÇÃO EM FOGÕES TRADICIONAIS E EM FOGÕES ECOEFICIENTES

Título
[en] STUDY OF INDOOR AIR QUALITY IN KITCHENS THAT USE FIREWOOD FOR COOKING ON TRADITIONAL STOVES AND ECO-EFFICIENT STOVES

Autor
[pt] LUIZ FELIPE DE MENEZES C DA SILVA

Vocabulário
[pt] MATERIAL PARTICULADO

Vocabulário
[pt] TECNOLOGIA DE TRANSICAO

Vocabulário
[pt] QUALIDADE DO AR

Vocabulário
[pt] BIOMASSA

Vocabulário
[en] PARTICULATE MATTER

Vocabulário
[en] TRANSITION TECHNOLOGY

Vocabulário
[en] AIR QUALITY

Vocabulário
[en] BIOMASS

Resumo
[pt] O estudo avaliou a melhoria na qualidade do ar com a substituição do fogão a lenha tradicional por um modelo ecoeficiente. O monitoramento foi realizado em duas fases: em julho de 2022, durante o uso do fogão tradicional, e em julho de 2023, com o fogão ecoeficiente, ambos na comunidade quilombola do Calolé, Cachoeira, BA. Como comparação, residências com fogões a GLP em São Gonçalo também foram analisadas. Sensores em tempo real mediram poluentes como Material Particulado (MP(2.5) e MP(10)), Dióxido de Carbono (CO2) e Formaldeído (HCHO), além de temperatura e umidade, com coleta adicional de MP(2.5) usando bomba de exposição. O material particulado apresentou maior variação entre os combustíveis. A troca para o fogão ecoeficiente reduziu significativamente a carga de poluentes nas cozinhas: MP(2.5) caiu de 138 mais ou menos 216 microg m(-3) para 45 mais ou menos 154 microg m(-3) e MP(10) de 202 mais ou menos 287 microg m(-3) para 59 mais ou menos 191 microg m(-3). Também foram observadas reduções de CO2 (477 mais ou menos 62 ppm para 443 mais ou menos 34 ppm) e HCHO (0,004 mais ou menos 0,004 mg m(-3) para 0,006 mais ou menos 0,002 mg m (-3)). A análise química do material particulado indicou a presença de hidrocarbonetos policíclicos aromáticos (HPA). O consumo de lenha reduziu em até 52 por cento após a troca do fogão. As concentrações médias observadas para fogões a GLP foram ainda menores: 12 mais ou menos 29 microg m(-3) para MP(2.5), 18 mais ou menos 41 microg m(-3) para MP(10), 506 mais ou menos 125 ppm para CO₂ e 0,013 mais ou menos 0,010 mg m(-3) para HCHO.

Resumo
[en] The study evaluated the improvement in air quality following the replacement of traditional firewood stoves with an eco-efficient model. Monitoring was conducted in two phases: in July 2022, during the use of traditional stoves, and in July 2023, with eco-efficient stoves, both in the Calolé quilombola community, Cachoeira, BA. As a comparison, households using LPG stoves in São Gonçalo were also analyzed. Real-time sensors measured pollutants such as Particulate matter (PM(2.5) and PM(10),), Carbon Dioxide (CO2), and Formaldehyde (HCHO), along with temperature and humidity, with additional PM(2.5) samples collected using an exposure pump. Particulate matter showed the greatest variation among the fuels. The shift to eco-efficient stoves significantly reduced pollutant loads in the monitored kitchens: PM(2.5) decreased from 138 more or less 216 microg m(-3) to 45 more or less 154 microg m(-3), and PM(10) from 202 more or less 287 microg m(-3) to 59 more or less 191 microg m(-3). Reductions in CO2 (from 477 more or less 62 ppm to 443 more or less 34 ppm) and HCHO (from 0.004 more or less 0.004 mg m(-3) to 0.006 more or less 0.002 mg m(-3)) were also observed. Chemical analysis of the collected particulate matter indicated the presence of polycyclic aromatic hydrocarbons (PAHs). Firewood consumption decreased by 52 percent following the stove replacement. The average concentrations for LPG stoves were even lower: 11.6 more or less 29 microg m(-3) for PM(2.5), 18 more or less 41 microg m(-3) for PM(10), 506 more or less 125 ppm for CO₂, and 0.013 more or less 0.01 mg m(-3) for HCHO.

Orientador(es)
ADRIANA GIODA

Coorientador(es)
ALEX RUBEN HUAMAN DE LA CRUZ

Banca
ADRIANA GIODA

Banca
SANDRA DE SOUZA HACON

Banca
SAMIRA DA GUIA MELLO PORTUGAL

Catalogação
2024-12-16

Apresentação
2024-09-20

Tipo
[pt] TEXTO

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=68823@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=68823@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.68823


Arquivos do conteúdo
NA ÍNTEGRA PDF