Título
[pt] ESTUDO EXPERIMENTAL SOBRE A DEGRADAÇÃO DE POLÍMERO REDUTOR DE ATRITO EM ESCOAMENTOS TURBULENTOS EM DUTOS
Título
[en] EXPERIMENTAL STUDY ON THE DEGRADATION OF FRICTION-REDUCING POLYMERS IN TURBULENT FLOW IN PIPELINES
Vocabulário
[pt] DEGRADACAO
Vocabulário
[pt] ADICAO DE POLIMEROS
Vocabulário
[pt] ESCOAMENTO TURBULENTO
Vocabulário
[pt] ESCOAMENTO EM DUTO
Vocabulário
[pt] REDUCAO DE ATRITO
Vocabulário
[en] DEGRADATION
Vocabulário
[en] ADDITION POLYMERS
Vocabulário
[en] TURBULENT FLOW
Vocabulário
[en] PIPELINE FLOW
Vocabulário
[en] FRICTION REDUCTION
Resumo
[pt] O escoamento de líquidos em dutos é crucial para a indústria, agricultura,
abastecimento de água e saneamento. Em dutos longos, a perda por atrito com a
parede é a principal causa da queda de pressão e do aumento do consumo de energia.
A adição de polímeros de cadeia longa para reduzir o atrito em escoamentos
monofásicos é conhecida desde 1948 pelo trabalho de Tom [1]. A redução do atrito
por adição de polímeros em escoamentos bifásicos é, contudo, menos explorada na
literatura. Este trabalho visa contribuir para o entendimento dos efeitos da injeção
de polímeros redutores de atrito em escoamentos bifásicos gás-líquido. Faz parte de
um estudo mais amplo que acopla informações sobre a redução de atrito na fase
líquida a uma metodologia para prever a redução de atrito em escoamentos bifásicos
gás-líquido. O trabalho realizado teve como foco a avaliação do desempenho de um
polímero redutor de atrito usado pela indústria de óleo e gás, o poli-isobuteno. O
estudo avaliou o potencial de redução de atrito na fase líquida do polímero e sua
degradação por cisalhamento contínuo e turbulência. Os testes foram realizados em
uma bancada de testes existente no laboratório. A configuração inovadora dessa
bancada consiste em um tubo circular girante, que fornece resultados equivalentes
aos de bancadas convencionais, utilizando quantidades menores de produtos e sem
a necessidade de bombas para manter o fluido em movimento, minimizando a
degradação do polímero. Os resultados de qualificação mostraram o bom
desempenho da bancada projetada. Os testes com o polímero com concentrações de
100, 200 e 300 ppm apresentaram reduções de atrito iniciais da ordem de 20%, 65%
decaindo e 80%. Estes resultados apontam para a viabilidade do uso do produto em
escoamentos bifásicos. No entanto, estudos adicionais de longa duração são
recomendados para a avaliação da degradação do produto.
Resumo
[en] Liquid flow through pipelines is of great relevance to industry, agriculture,
water supply and sewage systems. In the case of long pipelines, wall friction is
responsible for nearly the totality of the pressure drop and, consequently, the energy
consumption required to transport the fluids. Drag reduction by the addition of longchain polymers to single phase liquid flow has been known since 1948 after the
work of Tom [1]. Drag reduction by polymer addition in gas-liquid two phase flow
is, however, less explored in the literature. The main objective of the present work
is to contribute to the understanding of the effects of injecting drag reducing
polymers in two-phase gas-liquid flow. This work is part of a broader study where
information on single phase drag reduction is used in a methodology to predict drag
reduction in two-phase gas-liquid flows. The focus of the present work was on the
analysis of the performance of a commercial drag reduction agent used by the
oil/gas industry, the poly-isobuthene. The study was directed to the assessment of
the drag reduction potential of the polymer , and its degradation by the continued
shear against the wall and turbulence. The tests were conducted using an innovative
test section configuration available in the laboratory. This test section is formed by
a rotating wheel that yields results equivalent to those obtained from conventional
long loops that use large quantities of product and require pumps to maintain the
flow promoting additional polymer degradation. The test section was modified to
allow the use a more accessible torque meter, but of similar uncertainty as the
original sensor. The preliminary qualification results demonstrated the good
performance of the designed test section. The tests with poly-isobuthene polymer
with concentrations of 100, 200 and 300 ppm presented levels of drag reduction of
the order of 20%, 65% and 80%. These results point to the viability of the use of
the product in two-phase flows. However, additional long-duration tests are
recommended to fully assess the product degradation.
Orientador(es)
LUIS FERNANDO ALZUGUIR AZEVEDO
Coorientador(es)
IGOR BRAGA DE PAULA
Catalogação
2024-07-09
Tipo
[pt] TEXTO
Formato
application/pdf
Idioma(s)
PORTUGUÊS
Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=67244@1
Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=67244@2
Referência DOI
https://doi.org/10.17771/PUCRio.acad.67244
Arquivos do conteúdo
NA ÍNTEGRA PDF