Maxwell Para Simples Indexação

Título
[en] MINIMUM SYNCHRONOUS INERTIA MONITORING AND CALCULATION SYSTEM FOR REAL-TIME DECISION MAKING

Título
[pt] SISTEMA DE MONITORAÇÃO E CÁLCULO DE INÉRCIA MÍNIMA SINCRONIZADA PARA A TOMADA DE DECISÃO EM TEMPO REAL

Autor
[pt] RAPHAEL BOTTINO ARCOS

Vocabulário
[pt] RESERVA DE POTENCIA OPERATIVA

Vocabulário
[pt] SIMULACAO DINAMICA DE CONTINGENCIAS

Vocabulário
[pt] INERCIA SINCRONIZADA

Vocabulário
[pt] OPERACAO EM TEMPO REAL

Vocabulário
[pt] CONTROLE DE FREQUENCIA

Vocabulário
[en] OPERATING POWER RESERVE

Vocabulário
[en] DYNAMIC SIMULATION OF CONTINGENCIES

Vocabulário
[en] REAL-TIME OPERATION

Vocabulário
[en] FREQUENCY CONTROL

Resumo
[pt] Centros de operação ao redor do mundo têm verificado o aumento da complexidade ao longo dos anos, principalmente pela grande quantidade de novas informações que devem ser consideradas. No sistema elétrico brasileiro não é diferente, impactado pela participação cada vez mais ativa de fontes renováveis, como eólicas e fotovoltaicas, além de elos de corrente contínua. Seguindo uma tendência global, a consideração de valores de inércia sincronizada para a avaliação do desempenho da frequência e de fluxos sistêmicos se faz necessária, configurando-se como uma nova informação a ser exposta à operação em tempo real. Visando garantir mais segurança e confiabilidade ao ambiente de tempo real, o presente trabalho tem como objetivo traduzir os estudos realizados pela equipe de planejamento do ONS para a operação, através de um sistema capaz de monitorar parâmetros como a inércia sincronizada, reserva de potência operativa e outras informações associadas, ampliando a consciência situacional dos usuários. Além disso, o sistema deve promover simulações de contingências severas que possam provocar atuações de esquemas de corte de carga e indicar ações que possam ser realizadas para mitigar o problema.

Resumo
[en] Operation centers around the world have verified an increase of the complexity throughout the years, mostly due to huge amounts of new information that must be considered. The Brazilian electric system is no different, impacted by the increasingly active participation of renewable sources, such as wind and photovoltaic, as well as direct current links. Following a global trend, the consideration of values of synchronous inertia for the evaluation of the performance of the frequency is necessary, configuring as a new information to be exposed to real-time operation. With the purpose of guaranteeing more safety and reliability to the real-time environment, this work has the goal of translating the studies carried out by the ONS planning team to the operation, through a system capable of monitoring parameters such as synchronous inertia, operating reserve and other associated informations, increasing users situational awareness. Besides that, the system must promote simulations of severe contingencies that may trigger load shedding schemes and indicate actions that can be taken to soften the problem.

Orientador(es)
RICARDO BERNARDO PRADA

Coorientador(es)
LUIZ CLAUDIO DE ARAUJO FERREIRA

Banca
RICARDO BERNARDO PRADA

Banca
JORGE LUIZ DE ARAUJO JARDIM

Banca
JULIO CESAR STACCHINI DE SOUZA

Banca
LUIZ CLAUDIO DE ARAUJO FERREIRA

Catalogação
2022-10-27

Apresentação
2022-08-18

Tipo
[pt] TEXTO

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=60983@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=60983@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.60983


Arquivos do conteúdo
NA ÍNTEGRA PDF