Título
[pt] DESENVOLVIMENTO DE UM SENSOR DE GÁS BASEADO EM GRAFENO CVD
Título
[en] DEVELOPMENT OF A GAS SENSOR BASED ON CVD GRAPHENE
Autor
[pt] GIL CAPOTE MASTRAPA
Vocabulário
[pt] ESPECTROSCOPIA RAMAN
Vocabulário
[pt] DEFEITOS
Vocabulário
[pt] POLIURETANO
Vocabulário
[pt] SENSOR DE GAS
Vocabulário
[pt] GRAFENO CVD
Vocabulário
[en] RAMAN SPECTROSCOPY
Vocabulário
[en] DEFECTS
Vocabulário
[en] POLYURETHANE
Vocabulário
[en] GAS SENSOR
Vocabulário
[en] CVD GRAPHENE
Resumo
[pt] Neste trabalho foi obtido um sensor de gás baseado no grafeno crescido por CVD. Amostras foram transferidas usando o polímero Poliuretano (PU) como camada de sacrifício, sendo confirmada a eficácia do método proposto quando comparado com aqueles existentes na literatura. Foi confirmada a qualidade do filme monocamada transferido mediante o controle dos defeitos gerados durante a transferência e a fabricação do dispositivo. Foram depositados sobre o grafeno contatos na forma de um circuito interdigitado
e estudada a mudança da resistência do sensor construído para gases de NO2 e NH3. Espectroscopia Raman foi usada também neste trabalho para investigar o impacto da densidade dos defeitos no filme de grafeno na
resposta do sensor de gás. O dispositivo proposto foi capaz de detectar baixas concentrações dos gases alvo testados.
Resumo
[en] In this work a gas sensor based on graphene grown by CVD was obtained. Samples were transferred using Polyurethane (PU) polymer as the sacrificial layer, and the ecacy of the proposed method was confirmed when compared with those in the literature. The quality of the transferred monolayer film was confirmed by controlling the defects generated during the transfer and fabrication of the device. Contacts were deposited on top of the transferred film in the form of an interdigitated circuit and the sensor s resistance evolution was studied in the presence of NO2 and NH3. Raman spectroscopy was also used to investigate the impact of graphene defects density on the gas sensor response. The proposed device was able to detect low concentrations of the tested target gases.
Orientador(es)
FERNANDO LAZARO FREIRE JUNIOR
Banca
FERNANDO LAZARO FREIRE JUNIOR
Banca
DANTE FERREIRA FRANCESCHINI FILHO
Banca
MARCELO EDUARDO HUGUENIN MAIA DA COSTA
Banca
DANIEL LORSCHEITTER BAPTISTA
Banca
RUBEM LUIS SOMMER
Catalogação
2019-01-11
Apresentação
2018-07-20
Tipo
[pt] TEXTO
Formato
application/pdf
Idioma(s)
PORTUGUÊS
Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=36055@1
Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=36055@2
Referência DOI
https://doi.org/10.17771/PUCRio.acad.36055
Arquivos do conteúdo
NA ÍNTEGRA PDF