Maxwell Para Simples Indexação

Título
[pt] DESENVOLVIMENTO DE UM SENSOR DE GÁS BASEADO EM GRAFENO CVD

Título
[en] DEVELOPMENT OF A GAS SENSOR BASED ON CVD GRAPHENE

Autor
[pt] GIL CAPOTE MASTRAPA

Vocabulário
[pt] ESPECTROSCOPIA RAMAN

Vocabulário
[pt] DEFEITOS

Vocabulário
[pt] POLIURETANO

Vocabulário
[pt] SENSOR DE GAS

Vocabulário
[pt] GRAFENO CVD

Vocabulário
[en] RAMAN SPECTROSCOPY

Vocabulário
[en] DEFECTS

Vocabulário
[en] POLYURETHANE

Vocabulário
[en] GAS SENSOR

Vocabulário
[en] CVD GRAPHENE

Resumo
[pt] Neste trabalho foi obtido um sensor de gás baseado no grafeno crescido por CVD. Amostras foram transferidas usando o polímero Poliuretano (PU) como camada de sacrifício, sendo confirmada a eficácia do método proposto quando comparado com aqueles existentes na literatura. Foi confirmada a qualidade do filme monocamada transferido mediante o controle dos defeitos gerados durante a transferência e a fabricação do dispositivo. Foram depositados sobre o grafeno contatos na forma de um circuito interdigitado e estudada a mudança da resistência do sensor construído para gases de NO2 e NH3. Espectroscopia Raman foi usada também neste trabalho para investigar o impacto da densidade dos defeitos no filme de grafeno na resposta do sensor de gás. O dispositivo proposto foi capaz de detectar baixas concentrações dos gases alvo testados.

Resumo
[en] In this work a gas sensor based on graphene grown by CVD was obtained. Samples were transferred using Polyurethane (PU) polymer as the sacrificial layer, and the ecacy of the proposed method was confirmed when compared with those in the literature. The quality of the transferred monolayer film was confirmed by controlling the defects generated during the transfer and fabrication of the device. Contacts were deposited on top of the transferred film in the form of an interdigitated circuit and the sensor s resistance evolution was studied in the presence of NO2 and NH3. Raman spectroscopy was also used to investigate the impact of graphene defects density on the gas sensor response. The proposed device was able to detect low concentrations of the tested target gases.

Orientador(es)
FERNANDO LAZARO FREIRE JUNIOR

Banca
FERNANDO LAZARO FREIRE JUNIOR

Banca
DANTE FERREIRA FRANCESCHINI FILHO

Banca
MARCELO EDUARDO HUGUENIN MAIA DA COSTA

Banca
DANIEL LORSCHEITTER BAPTISTA

Banca
RUBEM LUIS SOMMER

Catalogação
2019-01-11

Apresentação
2018-07-20

Tipo
[pt] TEXTO

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=36055@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=36055@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.36055


Arquivos do conteúdo
NA ÍNTEGRA PDF