Título
[en] NUMERICAL SIMULATION OF A VAPOR-COMPRESSION REFRIGERATION SYSTEM USING A MIXTURE OF R134A REFRIGERANT AND NANOLUBRICANT POE/TIO2
Título
[pt] SIMULAÇÃO NUMÉRICA DE UM SISTEMA DE REFRIGERAÇÃO POR COMPRESSÃO DE VAPOR UTILIZANDO UMA MISTURA DE REFRIGERANTE R134A E NANOLUBRIFICANTE POE/TIO2
Autor
[pt] IGOR SZCZERB
Vocabulário
[pt] MODELAGEM
Vocabulário
[pt] NANOLUBRIFICANTE
Vocabulário
[pt] NANOFLUIDO
Vocabulário
[pt] NANOPARTICULA
Vocabulário
[pt] REFRIGERACAO
Vocabulário
[en] MODELLING
Vocabulário
[en] NANOLUBRICANT
Vocabulário
[en] NANOFLUID
Vocabulário
[en] NANOPARTICLE
Vocabulário
[en] REFRIGERATION
Resumo
[pt] O presente trabalho apresenta um modelo de simulação numérica para um sistema de refrigeração por compressão de vapor, operando com uma mistura de fluido refrigerante (R134a) e nanolubrificante, composto por óleo poliol éster (POE) como fluido base contendo nanopartículas de TiO2 em suspensão. Para o estudo dos trocadores de calor, foi utilizado o método de análise local, onde o condensador e o evaporador foram divididos em volumes de controle para os quais foram aplicadas as equações fundamentais de conservação de massa, energia e quantidade de movimento. Um modelo semi-empírico baseado em parâmetros característicos foi utilizado para modelar o compressor rotativo. A solução do sistema, de equações algébricas não lineares, foi implementada no software EES (Engineering Equation Solver). Os resultados do modelo de simulação foram comparados com dados experimentais disponíveis na literatura, obtendo-se um erro mínimo de 0,68 por cento para a taxa de transferência de calor no evaporador, e um erro máximo de 11,3 por cento no consumo de energia. O erro na temperatura de descarga do compressor variou de 2,91 a 8,83 graus Celsius.
Resumo
[en] The present work describes the numerical simulation of a heat pump refrigeration system, working with a mixture of refrigerant (R134a) and nanolubricant. The latter is composed of Polyolester (POE) oil as the base fluid containing TiO2 nanoparticles in suspension. In order to take into account the local variation of the two-phase heat transfer coefficient on the refrigerant side, the heat exchangers, condenser and evaporator, were divided into control volumes and, for each one of them, the fundamental equations of mass, energy and momentum were applied. A semi-empirical model was used to model the compressor. The resulting system of non-linear algebraic equations was implemented on the EES (Engineering Equation Solver) platform and an algorithm for the numerical solution was developed. The model was verified against experimental data available in the literature. A minimum error of 0,68 percent on the heat transfer rate in the evaporator, and a maximum of 11,3 percent for the energy consumption, were obtained. The error of the discharge temperature varied between 2,9 and 8,83 degrees Celsius.
Orientador(es)
JOSE ALBERTO DOS REIS PARISE
Coorientador(es)
PAUL ORTEGA SOTOMAYOR
Banca
JOSE ALBERTO DOS REIS PARISE
Banca
PAUL ORTEGA SOTOMAYOR
Banca
FLORIAN ALAIN YANNICK PRADELLE
Banca
FABIO TOSHIO KANIZAWA
Catalogação
2018-12-13
Apresentação
2018-05-09
Tipo
[pt] TEXTO
Formato
application/pdf
Idioma(s)
PORTUGUÊS
Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=35844@1
Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=35844@2
Referência DOI
https://doi.org/10.17771/PUCRio.acad.35844
Arquivos do conteúdo
NA ÍNTEGRA PDF