Título
[en] OPTIMIZATION OF THE ENERGY AND ENVIRONMENTAL SYSTEM OF A STEAM COMPRESSOR COOLING SYSTEM FROM NEW REFRIGERANT FLUIDS
Título
[pt] OTIMIZAÇÃO DO SISTEMA ENERGÉTICO E AMBIENTAL DE UM SISTEMA DE REFRIGERAÇÃO POR COMPRESSOR DE VAPOR A PARTIR DE NOVOS FLUIDOS REFRIGERANTES
Autor
[pt] WILLIAM BARBOSA CASSETTI JUNIOR
Vocabulário
[pt] REFRIGERACAO
Vocabulário
[pt] COEFICIENTE DE PERFORMANCE
Vocabulário
[pt] MODELO TERMODINAMICO
Vocabulário
[pt] POTENCIAL DE AQUECIMENTO GLOBAL
Vocabulário
[pt] MISTURA
Vocabulário
[pt] OTIMIZACAO
Vocabulário
[en] REFRIGERATION
Vocabulário
[en] PERFORMANCE COEFFICIENT
Vocabulário
[en] THERMODYNAMIC MODEL
Vocabulário
[en] GLOBAL WARMING POTENTIAL
Vocabulário
[en] MIXTURE
Vocabulário
[en] OPTIMIZATION
Resumo
[pt] No presente trabalho será desenvolvido um modelo termodinâmico de um sistema de refrigeração por compressão de vapor para aplicações de baixa temperatura (geladeira), baseado na primeira e segunda lei da termodinâmica, sendo o objetivo a comparar e estudar o desempenho do novos fluidos refrigerantes operando sistema de refrigeração projetado para operar com o fluido R134a. As duas variáveis a serem otimizadas são o COP (Coeficiente de performance) e GWP (Potencial de aquecimento global).Também serão analisadas as irreversibilidades do sistema proposto em nosso estudo.O método de gradiente reduzido generalizado (GRG) foi utilizado na solução do sistema de equações do modelo termodinâmico e o cálculo das propriedades termodinâmicas dos fluidos refrigerantes foi efetuado mediante as sub-rotinas do REFPROP (NIST Standard Reference Database 23, version 9.0).
Resumo
[en] In the present work a thermodynamic model of a vapor compression refrigeration system will be developed for low temperature (refrigerator) applications, based on the first and second law of thermodynamics, the objective being to compare and study the performance of the new refrigerating fluids operating system
designed to operate on the R134a fluid. The two variables to be optimized are the COP (Coefficient of Performance) and GWP (Global Warming Potential). Also the irreversibilities of the system proposed in our study will be analyzed. The generalized reduced gradient (GRG) method was used in the system solution of equations of the thermodynamic model and the calculation of the thermodynamic properties of the refrigerant fluids was carried out using the REFPROP (NIST Standard Reference Database 23, version 9.0).
Orientador(es)
JOSE ALBERTO DOS REIS PARISE
Coorientador(es)
PAUL ORTEGA SOTOMAYOR
Catalogação
2018-03-08
Tipo
[pt] TEXTO
Formato
application/pdf
Idioma(s)
PORTUGUÊS
Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=33236@1
Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=33236@2
Referência DOI
https://doi.org/10.17771/PUCRio.acad.33236
Arquivos do conteúdo