Maxwell Para Simples Indexação

Título
[pt] ANÁLISE DA RESISTÊNCIA DE PONTES FIXAS EM ZIRCÔNIA APLICADAS EM PRÓTESES DENTÁRIAS APARAFUSADAS

Título
[en] RESISTANCE ANALYSIS OF FIXED ZIRCONIA BRIDGES APPLIED IN SCREWED DENTAL PROSTHESIS

Autor
[pt] JOSE ALEX GONCALVES DE GALIZA

Vocabulário
[pt] ELEMENTO FINITO

Vocabulário
[pt] IMPLANTE DENTAL

Vocabulário
[pt] PROTESE DENTAL

Vocabulário
[pt] VIDA EM FADIGA

Vocabulário
[pt] ANALISE DE TENSAO

Vocabulário
[en] FINITE ELEMENTS

Vocabulário
[en] DENTAL IMPLANTS

Vocabulário
[en] DENTAL IMPLANTS

Vocabulário
[en] FATIGUE LIFE

Vocabulário
[en] STRESS ANALYSIS

Resumo
[pt] Esse trabalho teve como objetivo principal avaliar a resistência à falha da infraestrutura de uma prótese parcial fixa em zircônia de três elementos e aparafusada sobre implantes, através de análise de tensões por elementos finitos e determinação da resistência à fadiga da estrutura. Como objetivo secundário, foram avaliadas as distribuições das tensões nos demais componentes da prótese. Na análise de tensões, dois modelos distintos foram gerados, sendo o primeiro com prótese, implantes e parafusos similares àqueles adotados na clínica odontológica. Um segundo modelo, usado como controle, adotou uma geometria simplificada. As cargas mastigatórias foram aquelas usuais da literatura especializada e a análise por elementos finitos foi realizada através do programa Ansys Workbench 14.5. Os resultados das distribuições de tensões mostraram semelhanças entre os dois modelos, com pequenas variações relacionadas às geometrias empregadas. As tensões calculadas ficaram abaixo dos limites de resistência mecânica da zircônia e das ligas de titânio. No cálculo da vida em fadiga da prótese de zircônia um modelo analítico foi adotado prevendo uma vida infinita para o componente.

Resumo
[en] The main goal of this work was to evaluate the failure resistance of a zirconia fixed partial denture of three elements screwed on implants by means of a finite element stress analysis and the determination of the fatigue strength of the structure. As a secondary objective, the stress distributions in the other components of the prosthesis were evaluated. In order to promote the stress analysis, two different models were generated, the first making use of prosthesis, implants and screws similar to those adopted in the dental clinic. A second model, used as control, adopted a simplified geometry. The masticatory loads were those presented usually in the literature and finite element analysis was performed making use of Ansys Workbench 14.5 program. The stress distribution results showed similarity in both models, with small variations related to the adopted geometries. The calculated stresses were smaller than the ultimate strength of the zirconia and titanium alloys. Concerning the fatigue life of the zirconia prosthesis an analytical model was adopted and estimated an infinite life for the component.

Orientador(es)
MARCOS VENICIUS SOARES PEREIRA

Coorientador(es)
ARNALDO FREITAS CAMARÃO

Banca
MARCOS VENICIUS SOARES PEREIRA

Banca
JOSE ROBERTO MORAES D ALMEIDA

Banca
FATHI IBRAHIM DARWISH

Catalogação
2015-03-10

Apresentação
2014-04-25

Tipo
[pt] TEXTO

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=24242@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=24242@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.24242


Arquivos do conteúdo
NA ÍNTEGRA PDF