Maxwell Para Simples Indexação

Título
[en] A METHODOLOGY FOR METROLOGICAL EVALUATION AND DETERMINATION THE FREQUENCY OF CALIBRATION IN FISCAL AND ALLOCATION NATURAL GAS MEASUREMENT SYSTEMS

Título
[pt] METODOLOGIA PARA AVALIAÇÃO METROLÓGICA E DETERMINAÇÃO DA PERIODICIDADE DE CALIBRAÇÃO EM SISTEMAS DE MEDIÇÃO FISCAL E APROPRIAÇÃO DE GÁS

Autor
[pt] JOSE LUIZ DIAS

Vocabulário
[pt] METROLOGIA

Vocabulário
[pt] MEDICAO DE VAZAO

Vocabulário
[pt] INDUSTRIA DO PETROLEO

Vocabulário
[pt] PRESSAO

Vocabulário
[pt] INCERTEZA DE MEDICAO

Vocabulário
[pt] TEMPERATURA

Vocabulário
[en] METROLOGY

Vocabulário
[en] FLOW MEASUREMENT

Vocabulário
[en] PETROLEUM INDUSTRY

Vocabulário
[en] PRESSURE

Vocabulário
[en] UNCERTAINTY OF OF MEASUREMENT

Vocabulário
[en] TEMPERATURE

Resumo
[pt] No presente trabalho, de interesse da indústria de petróleo, é desenvolvida uma metodologia para avaliação metrológica e determinação da periodicidade de calibração em sistemas de medição de vazão de gás natural com placas de orifício, usando históricos de dados bimestrais de medidores instalados em pontos fiscais da bacia de Campos. O estudo analisa dados de calibração de medidores de temperatura, pressão e pressão diferencial de um transmissor eletrônico de vazão multivariável, contribuindo para o entendimento do impacto das incertezas destas variáveis na incerteza total do sistema de medição como um todo. Como resultados das avaliações metrológicas, foram determinados intervalos entre calibrações sucessivas, de modo que as exigências de incerteza de medição da portaria conjunta no 1 ANP/INMETRO de 19/6/2000 possam ainda ser atendidas nos pontos de medição fiscal e de apropriação . Inicialmente, foi mostrado que os valores de incertezas calculadas de vazão pela norma ISO 5167-2 (2003) atendem os requisitos da portaria. Finalmente, foi mostrado que o intervalo entre calibrações sucessivas dos medidores poderia ser aumentado do valor atualmente requerido pela portaria (2 meses) para pelo menos 6 meses para pressão diferencial e pressão, e 14 meses para temperatura. Este resultado tem um impacto econômico e operacional nas empresas de gás natural.

Resumo
[en] In the present work, of interest of the oil industry, a methodology was developed for metrological evaluating and determination the frequency of calibration of natural gas flow rate measurement systems with orifice plates, using calibration data obtained every two months from measurement instruments installed in fiscal points of the Campos Basin. The study evaluates the calibration data of temperature, pressure and differential pressure measurement from a multivariable transmitter, contributing to a better understanding of the influence of those variables in the uncertainty of flow rate as a result of the methodological evaluating, the intervals between two successive calibrations was determined, so that the requirements of the Portaria Conjunta n° 1 ANP/INMETRO, 19/06/2000, could be met in the fiscal and allocation points. First of all, it was shown that the flow rate uncertainty values, as calculated by ISO 5167-2 standard was fully covered by the requirements. Finally, it was shown the interval between successive calibrations could be increased of the value nowadays required by portaria (2 months) to 6 months for pressure and differential pressure, and to 14 months for temperature. This results has an economic and operational impact in the natural gas industry.

Orientador(es)
ALCIR DE FARO ORLANDO

Banca
MAURO SPERANZA NETO

Banca
ELOI FERNANDEZ Y FERNANDEZ

Banca
ALCIR DE FARO ORLANDO

Banca
PAULA MEDEIROS PROENCA DE GOUVEA

Catalogação
2007-12-13

Apresentação
2007-04-11

Tipo
[pt] TEXTO

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Formato
application/pdf

Idioma(s)
PORTUGUÊS

Referência [pt]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=11027@1

Referência [en]
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=11027@2

Referência DOI
https://doi.org/10.17771/PUCRio.acad.11027


Arquivos do conteúdo
CAPA, AGRADECIMENTOS, RESUMO, ABSTRACT, SUMÁRIO E LISTAS PDF
CAPÍTULO 1 PDF
CAPÍTULO 2 PDF
CAPÍTULO 3 PDF
CAPÍTULO 4 PDF
CAPÍTULO 5 PDF
REFERÊNCIAS BIBLIOGRÁFICAS E ANEXOS PDF